Goodman Mfg GSH13 warranty Product Specifications

Models: GSH13

1 8
Download 8 pages 293 b
Page 3
Image 3

Product Specifications

Specifications

 

GSH13

GSH13

GSH13

GSH13

GSH13

GSH13

GSH13

 

0181C*

0241C*

0301C*

0361C*

0421B*

0481B*

0601A*

 

 

 

 

 

 

 

 

Capacities and Ratings

 

 

 

 

 

 

 

Tonnage

2

3

4

5

Decibels

73

71

72

71

76

76

77

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

RLA

8.3

10.8

13.5

14.1

19.2

19.9

25.0

LRA

40.3

56.0

68.0

75.0

112.0

104.0

148.0

Type

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

 

 

 

 

 

 

 

 

Condenser Fan Motor

 

 

 

 

 

 

 

Horsepower

1/8

1/8

1/8

¼

¼

¼

1/6

FLA

0.7

0.7

0.7

1.5

1.5

1.5

1.1

 

 

 

 

 

 

 

 

Refrigerant System

 

 

 

 

 

 

 

Refrigerant Line Size

 

 

 

 

 

 

 

Liquid Line Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Line Size (“O.D.)

¾"

¾"

¾"

⅞"

1⅛"

1⅛"

1⅛"

Refrigerant Connection Size

 

 

 

 

 

 

 

Liquid Valve Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

⅜"

Suction Valve Size (“O.D.)

¾"

¾"

¾"

⅞"

⅞"

⅞"

⅞"

Valve Type

Sweat

Sweat

Sweat

Sweat

Sweat

Sweat

Sweat

Refrigerant Charge

127

122

130

188

246

208

233

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

Voltage-Phase (60 Hz)

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

208/230-1

Minimum Circuit Ampacity ²

11.1

14.2

17.6

19.1

25.5

26.4

32.3

Max. Overcurrent Protection ³

15

25

30

30

40

45

50

Min / Max Volts

197/253

197/253

197/253

197/253

197/253

197/253

197/253

Electrical Conduit Size

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

 

 

 

 

 

 

 

 

Equipment Weight (lbs)

142

147

146

146

152

152

278

Ship Weight (lbs)

159

164

164

164

170

170

300

 

 

 

 

 

 

 

 

¹ Tested and rated in accordance with AHRI Standard 210/240

²Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes

Always check the S&R plate for electrical data on the unit being installed.

Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.

Charge to be added for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECI-

FIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.