SS-GSX13

www.goodmanmfg.com

7

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

65ºF

 

 

75ºF

 

 

85ºF

 

 

95ºF

 

 

105ºF

 

 

115ºF

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet Bulb Temperature

 

 

 

 

 

 

 

 

 

IDB

Airflow

59

63

67

71

59

63

67

71

59

63

67

71

59

63

67

71

59

63

67

71

59

63

67

71

 

 

MBh

20.9

21.4

22.8

24.4

20.4

20.9

22.3

23.8

19.9

20.4

21.8

23.3

19.4

19.9

21.2

22.7

18.5

18.9

20.2

21.6

17.1

17.5

18.7

20.0

 

 

S/T

0.86

0.81

0.66

0.49

0.89

0.84

0.68

0.51

0.92

0.86

0.70

0.52

0.94

0.89

0.72

0.54

0.98

0.92

0.75

0.56

0.99

0.93

0.75

0.56

 

 

∆ T

24

23

20

16

24

23

20

16

24

23

20

16

24

23

20

16

24

23

20

16

22

21

19

15

 

700

kW

1.62

1.66

1.71

1.76

1.74

1.78

1.83

1.89

1.85

1.88

1.94

2.00

1.94

1.98

2.04

2.10

2.01

2.06

2.12

2.19

2.08

2.13

2.19

2.27

 

 

Amps

5.8

5.9

6.1

6.3

6.2

6.4

6.6

6.8

6.8

6.9

7.2

7.4

7.2

7.4

7.7

8.0

7.7

7.9

8.2

8.5

8.2

8.4

8.7

9.0

 

 

Hi PR

231

248

262

273

259

278

294

307

294

317

334

349

335

361

381

397

377

406

428

447

416

448

473

494

 

 

Lo PR

101

108

117

125

107

114

124

132

111

118

129

137

117

124

136

144

122

130

142

151

126

135

147

156

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

22.6

23.1

24.7

26.4

22.1

22.6

24.2

25.8

21.6

22.1

23.6

25.2

21.1

21.5

23.0

24.6

20.0

20.5

21.9

23.4

18.5

18.9

20.2

21.6

 

 

S/T

0.89

0.84

0.68

0.51

0.93

0.87

0.71

0.53

0.95

0.89

0.72

0.54

0.98

0.92

0.75

0.56

1.00

0.95

0.78

0.58

1.00

0.96

0.78

0.59

 

 

∆ T

23

22

19

15

24

23

20

16

24

23

20

16

24

23

20

16

23

22

19

16

21

21

18

15

80

800

kW

1.66

1.69

1.75

1.80

1.78

1.82

1.87

1.93

1.89

1.93

1.99

2.05

1.98

2.03

2.09

2.16

2.06

2.11

2.18

2.25

2.13

2.18

2.25

2.32

 

 

Amps

5.9

6.1

6.3

6.5

6.4

6.6

6.8

7.0

7.0

7.1

7.4

7.7

7.5

7.6

7.9

8.2

7.9

8.1

8.4

8.7

8.4

8.6

8.9

9.3

 

 

Hi PR

238

256

270

282

267

287

303

316

303

326

345

359

345

372

393

409

389

418

442

461

429

462

488

509

 

 

Lo PR

104

111

121

129

110

117

128

136

115

122

133

142

120

128

140

149

126

134

146

156

130

139

151

161

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

23.3

23.8

25.5

27.2

22.8

23.3

24.9

26.6

22.2

22.7

24.3

26.0

21.7

22.2

23.7

25.3

20.6

21.1

22.5

24.1

19.1

19.5

20.8

22.3

 

 

S/T

0.94

0.88

0.71

0.53

0.97

0.91

0.74

0.55

1.00

0.93

0.76

0.57

1.00

0.96

0.78

0.59

1.00

1.00

0.81

0.61

1.00

1.00

0.82

0.61

 

 

∆ T

22

21

19

15

23

22

19

15

23

22

19

15

22

22

19

15

21

22

19

15

20

20

17

14

 

900

kW

1.67

1.71

1.76

1.81

1.80

1.83

1.89

1.95

1.90

1.94

2.00

2.07

2.00

2.04

2.11

2.17

2.08

2.13

2.19

2.26

2.15

2.20

2.27

2.34

 

 

Amps

6.0

6.1

6.3

6.6

6.5

6.6

6.8

7.1

7.0

7.2

7.5

7.7

7.5

7.7

8.0

8.3

8.0

8.2

8.5

8.8

8.5

8.7

9.0

9.4

 

 

Hi PR

240

258

273

284

269

290

306

319

306

330

348

363

349

375

396

413

392

422

446

465

434

467

493

514

 

 

Lo PR

105

112

122

130

111

118

129

138

116

123

134

143

121

129

141

150

127

135

148

157

132

140

153

163

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

21.3

21.7

22.7

24.2

20.8

21.2

22.2

23.7

20.3

20.7

21.7

23.1

19.8

20.2

21.1

22.5

18.8

19.2

20.1

21.4

17.4

17.7

18.6

19.8

 

 

S/T

0.90

0.87

0.79

0.64

0.94

0.90

0.81

0.66

0.96

0.93

0.84

0.68

0.99

0.96

0.86

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.90

0.73

 

 

∆ T

25

25

23

20

26

25

24

21

26

25

24

21

26

25

24

21

25

25

24

20

23

23

22

19

 

700

kW

1.64

1.67

1.72

1.77

1.75

1.79

1.84

1.90

1.86

1.90

1.96

2.02

1.95

1.99

2.06

2.12

2.03

2.07

2.14

2.21

2.10

2.14

2.21

2.28

 

 

Amps

5.8

5.9

6.1

6.4

6.3

6.4

6.7

6.9

6.8

7.0

7.2

7.5

7.3

7.5

7.7

8.0

7.8

8.0

8.3

8.6

8.3

8.5

8.8

9.1

 

 

Hi PR

233

251

265

276

261

281

297

310

297

320

338

352

338

364

385

401

381

410

433

451

421

453

478

499

 

 

Lo PR

102

109

119

126

108

115

125

134

112

119

130

139

118

125

137

146

123

131

143

153

128

136

148

158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

23.0

23.5

24.6

26.2

22.5

22.9

24.0

25.6

22.0

22.4

23.5

25.0

21.4

21.9

22.9

24.4

20.4

20.8

21.7

23.2

18.9

19.2

20.1

21.5

 

 

S/T

0.94

0.90

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.96

0.87

0.70

1.00

0.99

0.89

0.73

1.00

1.00

0.93

0.75

1.00

1.00

0.94

0.76

 

 

∆ T

25

24

23

20

25

25

23

20

25

25

23

20

25

25

24

20

23

24

23

20

22

22

22

19

85

800

kW

1.67

1.71

1.76

1.81

1.80

1.83

1.89

1.95

1.90

1.94

2.00

2.07

2.00

2.04

2.11

2.17

2.08

2.13

2.19

2.26

2.15

2.20

2.27

2.34

 

 

Amps

6.0

6.1

6.3

6.6

6.5

6.6

6.8

7.1

7.0

7.2

7.5

7.7

7.5

7.7

8.0

8.3

8.0

8.2

8.5

8.8

8.5

8.7

9.0

9.4

 

 

Hi PR

240

258

273

284

269

290

306

319

306

330

348

363

349

375

396

413

392

422

446

465

434

467

493

514

 

 

Lo PR

105

112

122

130

111

118

129

138

116

123

134

143

121

129

141

150

127

135

148

157

132

140

153

163

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

23.7

24.2

25.3

27.0

23.2

23.6

24.8

26.4

22.6

23.1

24.2

25.8

22.1

22.5

23.6

25.1

21.0

21.4

22.4

23.9

19.4

19.8

20.7

22.1

 

 

S/T

0.98

0.95

0.86

0.69

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.76

1.00

1.00

0.97

0.79

1.00

1.00

0.98

0.80

 

 

∆ T

24

23

22

19

24

24

22

19

23

24

22

19

23

23

23

20

21

22

22

19

20

20

21

18

 

900

kW

1.69

1.72

1.77

1.83

1.81

1.85

1.90

1.96

1.92

1.96

2.02

2.09

2.02

2.06

2.12

2.19

2.10

2.14

2.21

2.28

2.17

2.22

2.29

2.36

 

 

Amps

6.0

6.2

6.4

6.6

6.5

6.7

6.9

7.2

7.1

7.3

7.5

7.8

7.6

7.8

8.0

8.4

8.1

8.3

8.6

8.9

8.6

8.8

9.1

9.5

 

 

Hi PR

242

261

275

287

272

293

309

322

309

333

352

367

352

379

400

418

396

427

450

470

438

471

498

519

 

 

Lo PR

106

113

124

132

112

120

131

139

117

124

136

144

123

131

143

152

129

137

149

159

133

142

154

165

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDB: Entering Indoor Dry Bulb Temperature

 

 

 

 

 

 

Shaded area reflects AHRI conditions

 

 

 

 

 

 

Amps = outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW = Total system power

Expanded Cooling Data GSX130241D* / CA*F1824*6D* (cont.)

Product Specifications

Page 7
Image 7
Goodman Mfg GSX130361E, GSX130481B, GSX130301B, GSX130421B Expanded Cooling Data GSX130241D* / CA*F1824*6D, 23.0, 393, 140

GSX130181E, GSX130301B, GSX130241D, GSX130361C, GSX130601B specifications

Goodman Manufacturing is renowned for producing reliable and efficient HVAC systems, and the GSX series of split system air conditioners is no exception. Among the standout models in this series are the GSX130481B, GSX130421B, GSX130611A, and GSX130361E. These units exemplify the blend of high performance and advanced technology that Goodman is known for, making them an excellent choice for residential cooling needs.

One of the key features of these Goodman units is their high efficiency ratings. With SEER (Seasonal Energy Efficiency Ratio) ratings typically ranging from 13 to 16, these air conditioners are designed to deliver noticeable energy savings while keeping indoor spaces comfortable. This efficiency not only lowers energy bills but also reduces the environmental impact associated with cooling.

Advanced compressor technology is another hallmark of the GSX series. Many of these models feature a reliable single-stage scroll compressor that operates smoothly and quietly. This design minimizes operational noise, ensuring that the unit maintains a comfortable indoor living environment without overwhelming occupants with sound. The GSX130611A, being a more powerful model in the lineup, stands out for its ability to effectively cool larger spaces while still adhering to energy-efficient standards.

Durability is a defining characteristic of Goodman’s split system air conditioners. These units come equipped with a galvanized steel cabinet, complete with a powder-coated finish that protects against rust and corrosion. This ensures longevity and performance under various weather conditions, making them suitable for a range of geographical locations.

Additionally, the GSX units are designed with ease of installation and maintenance in mind. The service-friendly design allows HVAC professionals to access key components without difficulty, streamlining necessary service or repairs. Features such as color-coded wiring and a powerful fan motor optimize airflow, enhancing overall performance.

The GSX series models also incorporate advanced refrigerant technology. Many of these units utilize R-410A refrigerant, which is known for its efficiency and environmental friendliness. This refrigerant is crucial in maintaining optimal performance while minimizing the carbon footprint of the cooling system.

Overall, the Goodman GSX130481B, GSX130421B, GSX130611A, and GSX130361E models stand out for their energy efficiency, durability, quiet operation, and innovative technology. They consistently offer homeowners an effective solution for achieving comfort and peace of mind in hot weather conditions. With their solid construction and reliable performance, Goodman air conditioners are an investment in quality HVAC solutions for years to come.