Model HUM-FP
INSTALLATION INSTRUCTIONS (cont'd.)
WARNINGS:
Shut off power before wiring.DO NOT wire the Model
UNLESS the board connections are 120 VAC. If, and only if, they are 120 VAC, install a receptacle and wire it to the board connections. Plug the
KXPLGLÀHULQWRWKHUHFHSWDFOHDO NOT, under any circumstances,wire the yellow solenoid wires to the curcuit board, or any other power source!
Wiring
Diagram A
11a. Wiring Diagram A:
Wiring
Diagram B
11b. Wiring Diagram B: Multi-Speed Blower.
For wiring with a
12.Tap into the water supply line using the saddle valve provided. Follow the directions on the saddle valve bag.
13
14
13.Connect copper tub- ing from the saddle valve to the solenoid valve. (Do not use plastic tubing.) Check for leaks.
The saddle valve must be fully opened or closed. Do not use the valve to regu- ODWHZDWHUÁRZ
14.Attach a 1/2" I.D. vinyl hose and clamp to carry the
ÁXVKLQJZDWHUIURPWKHXQLWWR the drain. Be sure the drain hose has a constant pitch to
WKHÁRRUGUDLQTo avoid
GDPDJHWRWKHGUDLQÀWWLQJ do not use solvent type adhesives when connecting the plastic hose to the
KXPLGLÀHU15.Test operation. Check for water leaks. Be sure the humidistat is operating properly.