Graco 122193 15W034 Beacon Tower Kit Installation, Install Beacon on EasyKey, Beacon Signals

Models: 122193

1 6
Download 6 pages 61.37 Kb
Page 2
Image 2
15W034 Beacon Tower Kit Installation

15W034 Beacon Tower Kit Installation

15W034 Beacon Tower Kit Installation

NOTE: Kit 15W034 is for ProMix 2KS manual systems.

1.Remove the 3/4 in. (19 mm) knockout on top of the EasyKey. Feed the wires through the hole and secure the beacon (1) with jam nuts (N) on the inside and outside of the box. See FIG. 1.

1

N

TI14040a

FIG. 1: Install Beacon on EasyKey

2.See FIG. 4. Install the din rail (7) with two screws (8). Install the header (5) on the din rail and connect the cable (4) to J5 on the EasyKey display board.

3.Connect yellow and gray wires from beacon to the power terminal. See FIG. 2.

4.Connect orange, brown, and red wires to header (5) pins 3, 4, and 5. See FIG. 6 on page 6.

5.To enable the optional audible alarm, connect sky blue wire to pin 3 on header (5). See FIG. 6 on page 6. When enabled, it will sound for all system alarms.

6.When beacon wiring is completed, insulate the end of each unused lead wire with insulation tape.

 

Beacon Signals

 

 

Flashing

 

Signal/

 

Audible

Description

 

 

Amber

A system warning is active; verify alarm.

 

 

Red

A potlife alarm exists. System goes to

 

Standby.

 

 

Green

Not used.

 

 

Audible

A system warning is active; verify alarm.

 

 

NOTE: See the ProMix 2KS operation manual for details of the specific alarms.

DC

OK

+

--

OUTPUT DC

Gray (Common)

AC

 

INPUT

N (-)

 

NC

 

NC

Yellow (+24V)

TI14041a

FIG. 2: Power Terminal Connections

2

313542D