Installation

CAUTION

Provide a bracket for mounting the air accessories. The fittings are not strong enough to support the accessories and may cause one or more to break.

NOTE: Install the accessories in the order shown in Figure 1.

DA pump runaway valve (H) shuts off the air to the pump if the pump accelerates beyond the pre-ad- justed setting. A pump which runs too fast can be seriously damaged.

DAn air line lubricator (G) provides automatic air motor lubrication.

DA bleed-type master air valve (F) relieves air trapped between it and the motor when the valve is closed. Order Part No. 107142.

DThe air regulator (E) controls pump speed and pressure.

DAn air line filter (D) removes harmful dirt and contaminants from your compressed air supply.

DA drain valve (L) is required near the pump fluid outlet to relieve fluid pressure in the pump, hose and gun. Order Part No. 210657.

DInstall an electrically conductive fluid hose (M) and spray gun (N).

Grounding

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment:

DPump: use a ground wire and clamp as shown below.

DTruck bed or platform: according to your local code.

DFluid hoses: use only electrically conductive hoses.

DAir compressor: follow manufacturer’s recommen- dations.

DSpray gun: grounding is obtained through connec- tion to a properly grounded fluid hose and pump.

DObject being sprayed: according to local code.

DFluid supply container: according to local code.

DAll solvent pails used when flushing or relieving pressure, always hold a metal part of the gun firmly to the side of a grounded metal pail, then trigger the gun.

To ground the pump:

To ground the pump, use a ground wire and clamp as shown below. Remove the ground screw (Z) and insert through the eye of ring terminal at end of ground wire

(Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 2. To order a ground wire and clamp, order Part No. 222011.

Z Y