Graco 24B327 Airless Spray Setup, Operation, Cleanup, Air Spray Setup

Models: 24B327

1 4
Download 4 pages 4.71 Kb
Page 2
Image 2

Airless Spray Setup

WARNING

To prevent injury when the applicator is not in use, always relieve pressure if sprayer is being shut down or left unattended.

Make sure pressure control is turned off and gasoline engine is shut off or power cord is unplugged from power source.

2.Loosen guard retaining nut.

3.Align guard (32) horizontally to spray a horizontal pattern.

4.Align guard (32) vertically to spray a vertical pattern.

(3) Horizontal

(4) Vertical

ti11908ati11909a

Refer to your sprayer instruction manual for priming and spray instructions.

Connect Applicator to Sprayer

1.Attach supply hose to sprayer fluid outlet.

2.Attach other end of supply hose to applicator swivel (13).

3.Refer to sprayer instruction manual for priming instructions.

Install Fluid Filter or Plug

1.When spraying fluids with small aggregates, install filter support (21) and filter (20, 20a) to reduce tip clogging.

2.When spraying with large spray tips and fluids with larger aggregates, install plug (20b) to prevent fluid from entering air passage in housing (1).

Install Applicator Tip and Guard

WARNING

1.If equipment has recently been operated, relieve pressure.

2.Using a pencil or similar object, insert seal

(25)into back of guard (32).

3.Install guard (32) onto end of applicator.

4.Insert tip (31) in guard (32). Tighten retaining nut.

Operation

Spraying

1.Be sure the arrow shaped tip (31) faces forward (spray).

2.Hold applicator perpendicular and approximately

40 in. (1 m) from surface. Move applicator first, then open applicator to spray a test pattern.

3.Slowly increase pump pressure until coverage is uniform and even (see sprayer instruction manual for additional information).

Aligning Spray

WARNING

1.Relieve pressure.

2

Clearing Clogs

WARNING

1.Relieve pressure (see Pressure Relief procedure).

2.Rotate tip (31) 180°. Open applicator into hopper or onto ground to remove clog.

3.Rotate tip (31) 180° back to spray position.

Cleanup

Thoroughly flush applicator after each work session before fluid begins to cure in applicator. Remove check valve (2) and clean all residue from air passages. Store in a dry location. Do not leave the applicator or any parts in water or cleaning solvents.

NOTE: Check valve (15) will be damaged if any object is inserted into valve.

Air Spray Setup

WARNING

To prevent injury when the applicator is not in use, always relieve pressure if sprayer is being shut down or left unattended.

Connect Applicator to Sprayer

1.Attach supply hose to sprayer fluid outlet.

2.Attach other end of supply hose to applicator swivel (13).

3.Install air hose to applicator check valve (15).

4.Refer to sprayer instruction manual for priming instructions.

Install Applicator Air Nozzle

WARNING

1.If equipment has recently been operated, relieve pressure.

2.Install air nozzle (10, 27, 28, 29) and retaining ring (11).

313537D

Page 2
Image 2
Graco 24B327 important safety instructions Airless Spray Setup, Operation, Cleanup, Air Spray Setup