Warnings
43A1333A
Install the Power CAN Cable

Non-IS Systems

1. Remove the user interface cable from J8 of the fluid
control module and plug it into connector P3 of the
USB module. See FIG. 2.
2. Connect Part No. 15V778 Cable (order separately)
to J8 of the fluid control module and to connector P4
of the USB module.
3. Close the Control Box. Restore power.
4. See your ProMix 2KE Operation manual for instruc-
tions on using the USB module.

IS Systems

1. Connect Part No. 15V782 Cable (order separately)
to J2 of the alternator module and to connector P3
of the USB module. See FIG. 3.
2. Close the Control Box. Restore power.
3. See your ProMix 2KE Operation manual for instruc-
tions on using the USB module.
FIG. 2. Install Part No. 15V778 Cable (Non-IS
Systems)
J8
P3
TI16580a
P4
TI16579a
USB Module
Fluid Control Module
To help prevent fire and explosion, do not connect,
download, or remove the USB flash drive unless the
unit is removed from the hazardous (explosive
atmosphere) location. Never leave the USB flash
drive in the USB port.
FIG. 3. Install Part No. 15V782 Cable (IS Systems)
TI15710a
J2
P3 TI16580a
USB Module Alternator Module