300 psi LPG Gas Gauge Installation for ThermoLazer
1.Close manual gas shutoff valve on propane tank, then disconnect gas supply hose (99) from propane tank.
99
ti14128a | ti22097a |
2.Unscrew gas supply hose (99) from bulkhead fitting (102).
99
102
ti22105a
3.Apply pipe sealant to tee fitting (11) and screw into bulkhead fitting (102). Screw in until gas tight. Install tee as shown.
11
ti22101a
4.Apply pipe sealant to bushing (6) and screw into tee fitting (11). Screw in until gas tight. Position gauge
(1) as shown.
1
6
11
ti22100a
NOTICE
Tighten by turning bushing (6) and holding tee fitting (11). Do NOT turn gauge (1). Damage to the gauge will occur.
5.Apply pipe sealant to filter fitting (10) and screw into tee fitting (11). Screw in until gas tight.
11 10
ti22098a
6.Apply pipe sealant to hose (99) and screw into filter fitting (10). Screw in until gas tight.
10 99
ti22099a
7. Connect gas supply hose (99) to propane tank.
99 |
ti14411b
8. Open manual gas shutoff valve on propane.
ti14127a
9.Check gas line for gas leaks (see ThermoLazer Operation Manual).
2 | 332653A |