![](/images/new-backgrounds/1062241/6224111x1.webp)
Installation
Refer to the Typical Installation drawing (Fig. 2).
WARNING
A
The
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient. Order Part No. 238635.
Mounting Accessories
Mount the pump (A) to suit the type of installation planned. The pump dimensions and mounting hole layout are shown on page 23.
Air and Fluid Hoses
Ensure that you have an adequate compressed air supply. Refer to the performance chart on page 20 to find the air consumption of your pump.
Be sure all air and fluid hoses are properly sized and
Connect an electrically conductive fluid hose (L) to the pump’s 3/8 npt(f) fluid outlet. Use of a short whip hose between the main fluid hose (L) and the gun (M) allows freer gun movement.
Connect a fluid suction hose or tube (N) to the pump’s 3/4 npt(m) fluid intake.
Use an electrically conductive 1/2 in. I.D. (minimum) air hose (H) to supply air to the pump.
Air Line Accessories
Install the following accessories in the order shown in Fig. 2, using adapters as necessary:
DAn air line lubricator (C) provides automatic air motor lubrication.
DA
DA pump runaway valve (B) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be seriously damaged.
DAn air regulator (E) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the
DAn air line filter (F) removes harmful dirt and moisture from the compressed air supply.
DA second
Fluid Line Accessories
Install the following accessories in the positions shown in Fig. 2, using adapters as necessary:
DA fluid drain valve (J) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING at left). Install the drain valve point- ing down, but so the handle points up when the valve is opened.
DA fluid filter (K) filters harmful particles from the fluid.
DA spray gun (M) dispenses the fluid. The gun shown in Fig. 2 is an airless spray gun.
6306981