8.Install whip hose and gun. Ensure that gun is grounded.
9.Connect hoses to proportioner.
10.Insulate and protect hoses. See Protective Covering, page 22.
Some previous models include trans- formers with tap settings.
Set transformer wire taps, using the following table. Transformer tap wire connections vary depending on length of heated hose. See pro- portioner operation manual for further informa- tion. Verify that tap wire connections are correct.
Single Side Heated | Tap Terminal | |
Hose Length, ft (m) | Label (ft) | |
|
| |
|
| |
50 (15.2) | 50 | |
|
|
|
100 | (30.5) | 50 |
|
|
|
150 | (45.7) | 100 |
|
|
|
200 | (61.0) | 100 |
|
|
|
250 | (76.2) | 150 |
|
|
|
300 | (91.5) | 150 |
|
|
|
350 | (106.8) | 200 |
|
|
|
400 | (122.0) | 200 |
|
|
|