Disassembly
Disassembly
Numbers and letters in parentheses refer to the fig-
ures and the parts list and drawing on page 9.
1.If pumps are not parked, press . Trigger gun until pumps stop. After fluid pressure drops below 700 psi (4.9 MPa, 49 bar), motor will run until pumps are at bottom of strokes, then shut off. Pump rod pins will be showing.
2. Turn main power OFF | . Disconnect power |
supply.
WARNING
Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinch- ing or amputation. Keep hands and fingers away from connecting rod during operation. Read warnings in Reactor operation manual.
3.Shut off both feed pumps. Close both fluid inlet ball valves (B).
B
4.Turn both PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF. Route fluid to waste containers or supply tanks. Ensure gauges drop to 0. Refer to Reactor operation manual.
SA
SB
TI2481a
Use dropcloth or rags to protect Reactor and sur- rounding area from spills.
5.Disconnect swivel elbow from pump A fluid inlet (C).
C
TI4174a
TI4174a
309911C | 3 |