![Installation](/images/new-backgrounds/32795/3279511x1.webp)
Installation
Installation
If this equipment is used in a
1.Install solvent flush kit
a.See FIG. 1. Install pump using mounting bracket (202) and hardware supplied. Mount bracket on wall, back of propor- tioner stand, or cart.
For wall mount, ensure that wall is strong enough to
support weight of equipment, fluid, hoses, and stress caused during operation. Mount at a conve- nient height for operation and maintenance, and so suction hose is not stretched tight. Ensure that equipment is level.
b.Connect suction hose (207) to elbow (206) at pump inlet. Place suction tube in container of solvent.
202
206
207
TI5675
FIG. 1: Solvent Flush Kit
2.Install feed kits
a.See FIG. 2. Install feed pump (101) in drum and secure with bung adapter (BA).
b.Install air control kit (104).
c.Screw swivel union (103) into pump fluid outlet. Connect hose (102) to swivel. Connect other end of hose to propor- tioner.
101
104
103
102
BA
TI5674
FIG. 2: Feed Pump
6 | 310863M |