Graco 312781E Rebuild the Mix Manifold, Replace the Outlet Tube and Static Mixer Tube

Models: 312781E

1 22
Download 22 pages 25.34 Kb
Page 12
Image 12

Repair

Rebuild the Mix Manifold

Manifold Rebuild Kit 15U931 is available. See page 15. Parts included in the kit are marked with a symbol, for example (3*). For best results, use all parts included in the kit.

See the Parts drawings on pages 14-19.Clean and inspect all parts. Apply pipe sealant to all pipe threads when reassembling.

1.Relieve pressure.

2.ProMix 2KS and ProMix 3KS only: Follow steps 2-6under Repair the Valves and Seats (ProMix 2KS and ProMix 3KS only), page 11. Do this for each of the valves.

3.ProMix 2KS and ProMix 3KS only: Remove the retaining ring (22) from the manifold block. Unscrew the shutoff valve handle (12). Remove the backup (14) and o-ring (13). Repeat for each side.

4.Remove the screws (23) and the manifolds (11, 8, or 36).

5.Note the orientation of the check valves (45). Remove the check valves and o-rings (5).

6.Install the new o-ring (5*) and check valve (45*). Reinstall the manifolds (11, 8, or 36).

7.Follow steps 2-5under Remove the Integrator Mixer, page 10.

NOTE: To replace the outlet tube (21) and the static mixer tube (24), see Replace the Outlet Tube and Static Mixer Tube, on page 12.

8.ProMix 2KS and ProMix 3KS only: Install the o-ring (13*), backup (14*), shutoff valve handle (12), and retaining ring (22) on each side.

9.ProMix 2KS and ProMix 3KS only: Install the o-rings (15*) and seats (16) for each of the valves (19).

10.ProMix 2KS and ProMix 3KS only: Reinstall the valves (19) and adapters (17) with the screws (20).

11.Reconnect the fluid and air lines.

Replace the Outlet Tube and Static Mixer Tube

See the Parts drawings on pages 14-19.If the outlet tube (21) or the static mixer tube (24) need replacement, both must be replaced.

1.Relieve pressure.

2.Unscrew the nut of the outlet tube (21) from the static mixer tube (24).

3.Remove the screws (30), cover (29), and clamp

(28).Remove the static mixer tube (24). Remove the static mixer (25) from the tube.

4.Remove the outlet tube (21) from the integrator cap

(49).Install the new outlet tube in the cap.

5.Install the static mixer (25) in the new tube (24).

6.Screw the outlet tube (21) nut and ferrule onto the static mixer tube (24) 1.25 turns past hand tight. This securely seats the ferrule on the tube.

7.Unscrew the nut from the tube (24). The ferrule will remain in place.

8.Screw the nut back onto the tube (24) 1.25 turns past hand tight.

9.Reassemble the clamp (28), cover (29), and screws

(30)to hold the tube (24) in place.

12

312781E

Page 12
Image 12
Graco 312781E important safety instructions Rebuild the Mix Manifold, Replace the Outlet Tube and Static Mixer Tube