Install Air Supply Kit
12 3A0235G
Install Air Supply Kit

T2 2:1, Husky 515, Husky 716,

and Husky 1050 Kits

1. Supply clean, dry filtered air to feed pumps.
2. See manual 309827 to install air supply kit.

Air Regulator Kit 248829

The air regulator kit (7) is only used with the Monark kits.
1. Install air regulator kit (7).
2. Interconnect tee fitting (1f) and quick disconnect fit-
ting (1b) on pump with air hose (1a).
Connect Air Lines
T2 2:1, Husky 515, Husky 716, and Husky 1050.
See manual 309827 to install air supply kit.
5:1 Monark Kits
1. Shut off air valves (V) at feed pumps (201).
2. Install air line (1a) with quick disconnect coupler
(1b) provided.
3. Connect air line and quick disconnect coupler to air
regulator (7).
Trapped air can cause the pump to cycle unexpect-
edly, which could result in serious injury from splash-
ing or moving parts.
V
201
1a r_256276_312769_2A
1b
7