Graco 3A2079A Parts Included in Kit, Part Number Description Qty Fitting

Models: 3A2079A

1 4
Download 4 pages 48.74 Kb
Page 3
Image 3

Connecting an RS Gun to an LPA2 System

Parts Included in Kit 125843

 

Part

 

 

 

Ref

Number

Description

Qty

Fitting

1

124803

JIC 04 (male) x

1

 

1/8 NPT (male)

 

 

 

 

 

2

22017-01

1/4 tube (male) x

1

 

1/8 npt (female)

 

 

 

 

 

3

7596-02

3/8 npt (male) x

1

 

1/4 npt (female)

 

 

 

 

 

4

LPA-143

1/4 tube (female) x

1

 

1/4 npt (female)

 

 

 

 

 

Installation

To reduce the risk of skin injection from high pressure fluid, perform Pressure Relief Procedure before connecting fittings. See RS gun manual 3A0232.

1.Install fitting 7596-02 (ref. 3) into the air manifold (B).

2.Remove the check valve (C) from the catalyst pump assembly (A) then install into fitting 7596-02 (ref. 3).

3.Install fitting LPA-143 (ref. 4) onto the check valve (C) removed in the previous step.

4.Remove the old catalyst pump connection hose from catalyst pump outlet (D).

5.Install fitting 22017-01 (ref. 2) into catalyst pump outlet (D).

6.Install fitting 124803 (ref. 1) into fitting 220127-01 (ref. 2).

7.Connect and configure air, material and catalyst hoses. See RS Gun manual 3A0232 for detailed instructions.

3A2079A

3

Page 3
Image 3
Graco 3A2079A important safety instructions Parts Included in Kit, Part Number Description Qty Fitting