Connecting an RS Gun to an LPA2 System
Parts Included in Kit 125843
| Part |
|
|
|
Ref | Number | Description | Qty | Fitting |
1 | 124803 | JIC 04 (male) x | 1 |
|
1/8 NPT (male) |
| |||
|
|
|
| |
2 | 1/4 tube (male) x | 1 |
| |
1/8 npt (female) |
| |||
|
|
|
| |
3 | 3/8 npt (male) x | 1 |
| |
1/4 npt (female) |
| |||
|
|
|
| |
4 | 1/4 tube (female) x | 1 |
| |
1/4 npt (female) |
| |||
|
|
|
|
Installation
To reduce the risk of skin injection from high pressure fluid, perform Pressure Relief Procedure before connecting fittings. See RS gun manual 3A0232.
1.Install fitting
2.Remove the check valve (C) from the catalyst pump assembly (A) then install into fitting
3.Install fitting
4.Remove the old catalyst pump connection hose from catalyst pump outlet (D).
5.Install fitting
6.Install fitting 124803 (ref. 1) into fitting
7.Connect and configure air, material and catalyst hoses. See RS Gun manual 3A0232 for detailed instructions.
3A2079A | 3 |