Graco Series A, 262854 important safety instructions Flush the Gun

Models: Series A

1 16
Download 16 pages 33.83 Kb
Page 8
Image 8
Flush the Gun

Operation

Flush the Gun

To reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, or static electric dis- charge when flushing:

Be sure the entire system, including flushing pails, is properly grounded.

Remove the tip guard and spray tip.

Maintain metal to metal contact between the gun and the flushing pail.

Use the lowest possible pressure.

ti19269a

7.Now trigger the gun into the flushing fluid supply pail. Circulate the fluid until the system is thoroughly flushed.

8.After gun is thoroughly flushed, relieve pressure.

NOTICE

Always flush the pump and gun before the sprayed fluid cures.

NOTE: This procedure requires a grounded pail of com- patible flushing fluid.

1.Relieve pressure.

2.Remove the tip guard and spray tip. Soak and clean the parts.

3.Single component systems only: Remove the pump intake from the original pail. Put the pump intake in a grounded pail of compatible solvent.

4.Start the pump at its lowest pressure.

5.Single component systems only: Trigger the gun into the original pail. When flushing fluid appears, release the trigger.

6.Two-component systems only: Trigger the gun into a waste container. When flushing fluid appears release the trigger.

8

3A2799A

Page 8
Image 8
Graco Series A, 262854 important safety instructions Flush the Gun