Maintenance
Diaphragm & Valve Actuator Replacement
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.
1.Relieve the pressure.
2.Remove the regulator from the fluid line.
3.Remove the six cap screws (19) from the regulator housing (24). See Fig. 2.
4.Remove the diaphragms (26 and 27). Inspect the carbide pin in the valve actuator (9) for wear. Replace if necessary.
5.Install the new diaphragms, with the PTFE diaphragm (26) facing toward the regulator housing (24), as shown in Fig. 2.
6.Install the valve actuator (9) and six cap screws (19). Torque the cap screws in the order shown in Fig. 2.
18
24
16
27
26
HytrelR
1*
Torque to
30 to 35
(41 to 47
19
HytrelR requires uniform compression. Torque each bolt no more than 1/8 turn at a time in the sequence shown. Repeat pattern until uniform torque of
9 | Torque Sequence |
| |
|
|
| |
PTFE | IN |
|
|
(white) | 6 | 1 |
|
|
| ||
| 4 | 3 |
|
HytrelR is a registered trademark of the DuPont Company. |
|
|
|
| 2 | 5 |
|
|
| OUT |
|
Fig. 2 |
|
| 7533A |
|
|
| |
|
| 307886 | 7 |