Install the Agitator

Always maintain a minimum of 1 in. (25.4 mm) clear- ance between rotating agitator parts and container to prevent sparks from contact.

1.Due to variability in drum heights the lowest set of blades may contact the bottom of the drum. If the bung adapter will not fully seat, or if resistance is felt when installing the agitator, move the blades up the shaft. To move the blades, loosen the setscrew on the hub and slide the assembly up or down to the desired position. The setscrew must always remain on the top, with the blades hanging down, so the blades will pass into and out of the bung hole.

ti14650a

FIG. 3. Adjust Location of Hub/Blade Assemblies

2.To install the agitator on the container cover, drop the folding blade sections through the drum bung hole, then screw the bung adapter into the bung hole. See Dimensions, page 9.

Installation

NOTICE

Keep the agitator tightly mounted to the drum bung to prevent damage to the threads from vibration.

When using a modified drum, check that there is no interference between the base of the drum and the shaft of the agitator to prevent blade or shaft dam- age and to avoid sparks from contact (see Warning under Install the Agitator).

3.Position the air motor so the air line can be attached easily to the needle valve’s 1/8 npt inlet, without obstructing any other system components.

4.Attach an air line quick disconnect valve or ball valve for main air shutoff. Order Part 208536, Coupler, and Part 169969, fitting.

5.Attach the air line between the needle valve’s 1/8 npt inlet and the 1/8 npt air supply manifold outlet.

To avoid personal injury, never operate the agitator outside of a drum.

Angled Adaptor

If the agitator is used on a drum with an off-center bung and the blades would contact the side of the drum, the angled adaptor must be used to avoid this contact.

1.Thread the locking ring onto the angled adaptor by hand, as far as it will go.

2.Thread the angled adaptor into the bung until it bot- toms out, then back it out until the widest portion on of the adaptor top is pointing just to the left of the center of the drum (Fig. 4).

3.Turn down the locking ring until it contacts the drum. Use an appropriately sized pipe wrench or adjust- able wrench to tighten the adaptor down until the widest portion of the adaptor top is in line with the drum.

Adaptor

ti16998a

FIG. 4. Angled Adaptor

313643G

5

Page 5
Image 5
Graco 24C728 B, Series B, 24C729 warranty Install the Agitator, Angled Adaptor

24C728 B, 24C729, Series B specifications

Graco Series B, 288046 is a top-tier product designed to meet the rigorous demands of various applications in industries such as manufacturing, automotive, and construction. Renowned for its reliability and efficiency, this product stands out due to its innovative features and robust technology.

One of the standout features of the Graco Series B, 288046 is its advanced air-powered design. This design allows for smooth and consistent fluid transfer, minimizing downtime and enhancing productivity. The air-driven operation not only offers greater control over the flow rates but also ensures that the system can operate in situations where electric power may be unavailable or impractical. This versatility makes it ideal for various work environments.

The Series B is equipped with a high-performance motor that delivers exceptional power output while maintaining energy efficiency. This feature is particularly advantageous for businesses looking to reduce operational costs without compromising on performance. The motor is engineered to handle different fluid viscosities, making the Series B versatile for use with a wide range of materials, including paints, adhesives, and sealants.

Durability and ease of maintenance are key characteristics of the Graco Series B, 288046. Constructed from high-quality materials, the product is built to withstand harsh conditions, ensuring a long-lasting lifespan. Additionally, its modular design simplifies maintenance and repairs, allowing for quick replacements of components and minimal disruption to operations.

Safety is another paramount consideration incorporated into the Series B design. It features comprehensive safety mechanisms that protect users and equipment alike, reducing the risk of accidents during operation. This is especially crucial in environments where workers are regularly handling hazardous materials.

Graco also emphasizes user-friendly functionality. The Series B showcases intuitive controls, enabling operators to quickly familiarize themselves with the system and operate it efficiently. The product also includes adjustable pressure settings, allowing for precise application suited to specific tasks.

In conclusion, the Graco Series B, 288046 is an exemplary solution for companies seeking a reliable, efficient, and safe fluid handling system. With its advanced technologies, user-friendly features, and robust construction, it offers unmatched performance across various industries, ensuring optimal productivity and safety.