Pressure ControlWARNING
INJECTION
HAZARD
T
o reduce the risk of serious injury
,
whenever you are instructed to relieve
pressure, follow the
Pressure Relief
Procedure
on page 9.
NOTE:
See Fig. 30 for this procedure.
NOTE:
The pressure control (64) cannot be repaired
or adjusted. If it has malfunctioned, replace it.
1.
Remove the front cover (13). Remove the screws
(56). Lower the junction box (59).
2.
Disconnect the harness connector (A) from the
motor start board (47).
3.
Remove the screws (63). Pull forward on the pres
-
sure adjusting knob and tip the pressure control
(64) forward and up to detach it from the drive
housing (1
1).
4.
Guide the harness (A) through the motor and drive
housing and remove the pressure control.
5.
Guide the harness of the new pressure control
through the drive housing and motor passages.
6.
Install the new pressure control. T
ip the pressure
control down and back into the drive housing (1
1).
Do not pinch or damage the harness (A).
7.
Loosely install the screws (63) and then torque
them to 21 in–lb (2.4 N.m).
8.
Install the front cover (13). Connect the harness
(A) to the motor start board (47).
9.
Install the junction box. Be sure no leads are
pinched against the motor or by the motor start
board.
64 63
59
56
A
13
11
Torque
to
21 in–lb (2.4 N.m)
Fig.
30
02816A