Grounding
309523D 5
Grounding
Check your local electrical code and pump/sprayer man-
ual for detailed grounding instructions.
Spray gun: ground through connection to a
grounded fluid hose and pump/sprayer.
Fluid hose: use only grounded hoses.
Fluid supply container: follow local code.
Object being sprayed: follow local code.
Gun Trigger Safety
WARNING
Read warnings, page 3.
Solvent flushing pails: follow local code. Use only
conductive metal pails placed on a grounded surface.
Do not place pail on a nonconductive surface, such
as paper or cardboard, which interrupts grounding
continuity.
To maintain grounding continuity when flushing
or relieving pressure: hold metal part of gun firmly
to side of grounded metal pail, then trigger gun.
Ti1102 1
WARNING
Read warnings, page 3.
Wallet-sized warning card with important injection
treatment information is included with the gun.
Additional cards are available at no charge. Pro-
vide a card to all operators.
To engage trigger lock: turn it to position A. If engaged,
gun will not trigger. Engage trigger lock whenever you
stop spraying to avoid accidental triggering.
To disengage trigger lock: turn it to position B.
A
Ti1950A
B
Ti1949A