Graco Inc 231-353, 390sts, 308-548 manual Drain Valve, Inlet Strainer Installation/Removal

Models: 390sts 231-353 308-548

1 36
Download 36 pages 52.55 Kb
Page 32
Image 32

Drain Valve

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief

Procedure on page 9.

42a

42b

 

 

￿

Apply thread sealant

 

 

 

Apply grease

 

￿

 

 

 

 

42d

 

2

to face of base

 

 

 

 

Torque into pump

 

 

 

42c

 

 

 

 

3

manifold to 185 in–lb

 

 

 

 

 

(21 N.m)

 

 

 

 

4

Handle shown

 

 

 

 

 

in closed position

 

42

 

 

 

2

3

 

 

 

 

43

44

Fig. 32

4

45

 

02819

1.Turn the handle (45) to the closed position. Drive out the pin (44). Remove the handle.

2.Remove the base (43).

3.Unscrew the drain valve (42). The gasket (42a) and seat (42b) will stay in the valve.

Repair

1.Unscrew the spring retainer from the valve body. Remove the spring, washers and stem/ball. Clean any debris from the ball or seat area.

2.If replacing the gasket (42a) or seat (42b), pry out the gasket.

NOTE: Whenever the gasket (42a) is removed, re- place it with a new one.

3.Coat the o-ring (42d) with grease. Press the stem into the valve body. Install the spring, washers and spring retainer into the valve body.

4.Place the seat (42b) in the valve body so the lapped side is toward the ball. Apply a small amount of grease to the new gasket (42a) and in- stall it in the valve body.

NOTE: The gasket will protrude from the end of the valve until the valve is tightened into pump, which cor- rectly seats the gasket.

Replacement

1.Apply a small amount of thread sealant (42e) onto the valve (42) threads. Tighten the valve into the pump manifold to 185 in–lb (21 N.m).

2.Lightly grease the face of the base (43) and install the base. Turn the stem so the pin hole is vertical.

3.Securely install the handle (45) and drive pin (44).

Inlet Strainer Installation/Removal

Installation (Fig. 33)

1.Align the keyway in the strainer (39) with the small nub near the end of the suction tube (32).

2.Push the strainer over the nub and up to the suc- tion tube’s raised band. While holding the strainer against the band, rotate it about 1/2 turn in either direction (a wrench may be necessary).

Removal

1.With a wrench or the hand, turn the strainer (39) in either direction until the keyway aligns with the raised nub in the suction tube (32). A sudden re- lease in turning resistance will be felt when the parts align.

2. Pull, or tap, the strainer straight off the suction

Fig. 33

 

tube.

 