![](/images/new-backgrounds/1209560/20956063x1.webp)
Drain Valve
WARNING
INJECTION HAZARD
To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief
Procedure on page 9.
42a | 42b |
|
| Apply thread sealant | |
|
|
| Apply grease | ||
|
|
| |||
|
| 42d |
| 2 | to face of base |
|
|
|
| Torque into pump | |
|
|
| 42c |
| |
|
|
| 3 | manifold to 185 | |
|
|
|
|
| (21 N.m) |
|
|
|
| 4 | Handle shown |
|
|
|
|
| in closed position |
| 42 |
|
|
| 2 |
3 |
|
|
|
|
43
44
Fig. 32 | 4 | 45 |
| 02819 |
1.Turn the handle (45) to the closed position. Drive out the pin (44). Remove the handle.
2.Remove the base (43).
3.Unscrew the drain valve (42). The gasket (42a) and seat (42b) will stay in the valve.
Repair
1.Unscrew the spring retainer from the valve body. Remove the spring, washers and stem/ball. Clean any debris from the ball or seat area.
2.If replacing the gasket (42a) or seat (42b), pry out the gasket.
NOTE: Whenever the gasket (42a) is removed, re- place it with a new one.
3.Coat the
4.Place the seat (42b) in the valve body so the lapped side is toward the ball. Apply a small amount of grease to the new gasket (42a) and in- stall it in the valve body.
NOTE: The gasket will protrude from the end of the valve until the valve is tightened into pump, which cor- rectly seats the gasket.
Replacement
1.Apply a small amount of thread sealant (42e) onto the valve (42) threads. Tighten the valve into the pump manifold to 185
2.Lightly grease the face of the base (43) and install the base. Turn the stem so the pin hole is vertical.
3.Securely install the handle (45) and drive pin (44).
Inlet Strainer Installation/Removal
Installation (Fig. 33)
1.Align the keyway in the strainer (39) with the small nub near the end of the suction tube (32).
2.Push the strainer over the nub and up to the suc- tion tube’s raised band. While holding the strainer against the band, rotate it about 1/2 turn in either direction (a wrench may be necessary).
Removal
1.With a wrench or the hand, turn the strainer (39) in either direction until the keyway aligns with the raised nub in the suction tube (32). A sudden re- lease in turning resistance will be felt when the parts align.
2. Pull, or tap, the strainer straight off the suction | Fig. 33 |
| |
tube. |
|
32
39
477