Graco Inc 800-639 Servicing the V-Packings, Must be purchased separately, Backflow Preventor

Models: 2540 308-529 3040 800-690 800-639 800-638

1 20
Download 20 pages 11.76 Kb
Page 19
Image 19
Servicing the V–Packings

Servicing the V–Packings

NOTE: There are two types of packing kits: one is packings only , the other includes the packings, rings and retainers.

1.Remove the manifold as outlined in the Pumping Section.

2.Carefully pull the packing retainer from the manifold. Examine the o–ring and replace it if it is cut or damaged.

3.Remove the v–packing and head ring. Pull out the intermediate retainer ring. Remove the second v–packing and second head ring.

4.Inspect all parts and replace as necessary.

ACCESSORIES

(Must be purchased separately)

DOWNSTREAM CHEMICAL INJECTOR KIT 800–117

For injecting harsh cleaning chemicals downstream from the pump.

UPSTREAM CHEMICAL INJECTOR KIT 800–257

For injecting mild cleaning chemicals upstream into the pump.

5.Thoroughly clean the packing cavities and examine for debris and damage.

6.Lightly grease the packing cavities and then replace the packings in the following order: head ring, v–packing, intermediate ring, head ring, v–packing and packing retainer with the o–ring installed in the retainer groove.

CAUTION

Install the parts in the proper order and facing the correct direction. Improperly installed parts will cause a malfunction.

7.Reassemble the manifold as instructed in Servicing the Plungers.

ANTI–FREEZE FLUSH KIT 802–327

For flushing system with 50% anti–freeze solution prior to transporting or storing pressure washer in below freezing temperatures.

INLET PRESSURE REGULATOR 800–258

Regulates inlet water pressure to 60 psi (4 bar) maximum.

BACKFLOW PREVENTOR 801–133

Prevent back–up of contaminated water into fresh supply. Install upstream of pump.

TECHNICAL DATA

 

Model 800–638

Model 800–690

Model 800–639

 

 

 

 

Engine (air–cooled, 4 cycle)

9 hp Honda OHV

9 hp Briggs & Stratton OHV

11 hp Honda OHV

 

 

 

 

Gasoline Tank Capacity

6.2 quarts (6 liters)

5 quarts (4.8 liters)

6.9 quarts (6.5 liters)

 

 

 

 

Water Pump Maximum Working

2500 psi (172 bar)

2500 psi (172 bar)

3000 psi (207 bar)

Pressure

 

 

 

Water Pump Maximum Flow

4 gpm (15 lpm)

4 gpm (15 lpm)

4 gpm (15 lpm)

 

 

 

 

Inlet Hose Connection

3/4” garden hose (f)

3/4” garden hose (f)

3/4” garden hose (f)

 

 

 

 

Weight

158 lb (70 kg)

158 lb (70 kg)

172 lb (78 kg)

 

 

 

 

Dimensions

36” (914 mm)

36” (914 mm)

36” (914 mm)

Length

Width

21” (533 mm)

21” (533 mm)

21” (533 mm)

Height

23.5” (597 mm)

23” (584 mm)

24” (610 mm)

Maximum Inlet Water Temperature

160_￿ F (70_￿ C)

160_￿ F (70_￿ C)

160_￿ F (70_￿ C)

 

 

 

 

Wetted Parts

 

 

 

High Pressure Hose

Acrylonitrile and Buna–N cover and tube

 

Bypass Hose

Synthetic yarn and EPDM

 

 

Pressure Washer

Anodized aluminum, Aluminum or bronze alloys, Brass Copper, Nylon–PTFEr

(including fittings)

composite, Ceramic, Buna–N, Cotton phenolic, 303, 304, and 316 Stainless steel,

 

Polymide–12 thermoplastic,PTFEr, Carbon steel, Zinc with or without yellow

 

chromate plate

 

 

 

PTFE is a registered trademark of the DuPont Company.

 

308–529 19

Page 19
Image 19
Graco Inc 800-639, 3040 Servicing the V-Packings, Must be purchased separately, Downstream Chemical Injector Kit, 308-529