Storage
22 312001G
StorageShort Term Storage
(up to 2 days)
1. Relieve pressure, page 9.
2. Leave suction tube and
prime tube in paint pail.
3. Cover paint pail and hoses
tightly with plastic wrap.
4.
a. Engage trigger
lock.
b. Leave gun
attached to
hose.
c. If you have not
already
cleaned them,
remove tip and
guard from
gun and clean with water or flushing sol-
vent. A soft brush can be used to loosen
and remove dried on material if needed.
d. Wipe paint off outside of gun using a soft
cloth moistened with water or flushing sol-
vent.
Long Term Storage
(more than 2 days)
1. Place suction tube in
Pump Armor storage
fluid bottle and prime
tube in waste pail.
2. Turn Prime/Spray valve
to PRIME.
3. Turn power switch ON.
4. Turn pressure control knob
clockwise until the pump
turns on.
5. When storage fluid comes
out of prime tube (5-10
seconds) turn power switch
OFF.
6. Turn Prime/Spray valve to
SPRAY to keep storage
fluid in sprayer during
storage.
ti9353a
ti9350a
ti9671a
ti8908a
(
SG20
)
ti8923a
(
SG10
)
• Always circulate Pump Armor storage fluid
through system after cleaning. Water left
in sprayer will corrode and damage pump.
• Follow Shutdown and Cleaning, page 17,
or Power Flush Cleaning, page 19.
ti2057a
ti9346a
ti5580a
ti9343a
ti9345a
ti2018a