18
CONTINUITY DIAGRAM
Model 927060, 062, 064

Solenoid

NOT ENERGIZED ENERGIZED

The diagrams below show the various states of connection for electrical components.

The solid lines on switches show continuity.

NOTE: All switches are viewed from the rear.

PTO Switch

Seat Switch

Relay

39
471
DISENGAGED
(down position)
39
471
ENGAGED
(up position)
1
OPERATOR
OFF SEAT
21
OPERATOR
ON SEAT
2
87
87A
86 85
30
NOT ENERGIZED
87
87A
86 85
30
ENERGIZED
OFF
MG
S2
BS1
A
RUN
MG
S2
BS1
A
START
MG
S2
BS1
A

Key Switch

(01563700)

OFF ON

Light Switch

(03656800)

Parking Brake Switch

(02777200)

1
2

(03042800)

(01545600)

(02754100)

(03679000)

1
2
ON
OFF

Brake Neutral Switch

12
BUTTON DOWN
12
BUTTON UP

(03657100)

PA0261