Greenheck Fan dimensions Model FSD-312, Combination Fire Smoke Dampers, Application, Ratings

Models: FSD-312

1 7
Download 7 pages 17.99 Kb
Page 1
Image 1
Model FSD-312

 

 

 

 

 

 

Model FSD-312

APPLICATION

Combination Fire Smoke Dampers

 

 

 

 

Steel Airfoil Blades

Model FSD-312 is a high performance combination fire smoke

 

 

 

 

 

 

UL 555S Leakage Class II

damper with class II leakage. High strength airfoil blades ensure the

 

 

 

 

UL555 112 Hour Fire Resistance Rating

lowest resistance to airflow in HVAC systems with velocities to 3000

 

fpm (15.2 m/s) and pressures to 4 in. wg (1 kPa) Model FSD-312 may

 

 

 

 

 

 

be installed vertically (with blades running horizontal) or horizontally

Model FSD-312 meets the requirements for fire

and is rated for airflow and leakage in either direction.

dampers, smoke dampers and combination fire

Ratings

 

smoke dampers established by:

 

National Fire Protection Association

UL 555 Fire Resistance Rating:

 

 

NFPA Standards 80, 90A, 92A, 92B, 101 & 105

Fire Rating:

1½ hours

IBC International Building Codes

Dynamic Closure Rating: Actual ratings are size dependent

Max. Velocity:

up to 3000 fpm (15.2 m/s)

ICBO Uniform Building Codes

Max. Pressure:

4 in. wg (1 kPa)

CSFM California State Fire Marshal

UL555S Leakage Rating:

 

Fire Damper Listing (#3225-0981:103)

 

Leakage (Smoke) Damper Listing (#3230-0981:104)

Leakage Class:

II

Operational Rating:

Actual ratings are size dependent

New York City (MEA listing #260-91-M)

Max. Velocity:

up to 3000 fpm (15.2m/s)

 

 

 

 

 

 

Max. Pressure:

4 in. wg (1 kPa)

 

 

 

 

 

 

Maximum Temperature: 350°F (177°C)- depending upon the

“UL CLASSIFIED (see complete marking on prod-

 

 

actuator

uct)”

 

 

 

 

 

Standard Construction

“UL CLASSIFIED to Canadian safety standards

(see complete marking on product)”

Frame:

5 in. x 1 in. (127mm x 25 mm)

Standard 555 & 555S (Listing #R13317)

 

 

galvanized steel hat channel with

 

 

 

 

 

 

 

 

reinforced corners. A low profile

 

 

Greenheck Fan Corporation certifies that the

 

 

head and sill are used on sizes less

 

 

 

 

than 17 in. (432mm)

 

 

model FSD-312 shown herein is licensed to

 

 

 

 

bear the AMCA Seal. The ratings shown are

Blades:

Double skin airfoil shape of

 

 

 

 

based on tests and procedures performed

 

 

galvanized steel with full length

 

 

in accordance with AMCA Publication 511

 

 

structural reinforcement. 14 ga.

 

 

and comply with the requirements of the

 

 

(2 mm) equivalent thickness.

 

 

AMCA Certified Ratings Programs. The

 

 

R

 

AMCA Certified Ratings Seal applies to air

Seals:

Extruded silicone rubber blade seals.

 

 

performance ratings only.

 

 

Flexible stainless steel jamb seals.

 

 

 

 

 

 

Linkage:

Concealed in jamb.

 

 

 

 

 

 

Closure Device:

RRL 165°F (74°C)

 

 

 

 

 

 

Axles:

1⁄2 in. (13mm) dia. plated steel.

 

 

 

 

 

 

Bearings:

Bronze sleeve type.

 

 

 

 

 

 

Size Limitations:

8 in. W x 6 in. H

 

 

 

 

 

 

Minimum Size:

 

 

 

 

 

 

Maximum Size:

(203 mm W x 152mm H)

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Section:

32 in. W x 50 in. H

 

 

 

 

 

 

 

 

(813mm W x 1270mm H)

 

 

 

 

 

 

Multiple Section:

96 in. W x 50 in. H

 

 

 

 

 

 

 

 

(2435mm W x 1270mm H)

 

 

 

 

 

 

Vertical Only:

128 in. W x 100 in. H

 

 

 

 

 

 

 

 

(3251mm W x 2540mm H)

 

 

 

 

 

 

Optional Features:

LH

 

 

 

H*

 

 

 

 

• RRL/OCI (Open closed indication switches)

 

 

 

 

• 165ºF (74°C), 212ºF (100°C), 250ºF (121°C), 350ºF (177°C) RRL’s

 

 

 

 

 

 

available

 

 

 

 

 

 

 

• TOR (remote override closure allows damper to perform smoke

 

 

 

 

 

 

management functions during a fire emergency.)

 

 

 

 

 

 

 

 

W*

 

 

 

• Electric or pneumatic actuators to accomplish smoke

 

 

 

 

 

management and system functions.

 

 

 

 

 

 

 

 

 

 

RH

• POC retaining angles

 

 

 

 

 

• Smoke detectors

 

*W&H dimensions furnished approximately 1/4 in. ( 6 mm) undersize.

• Momentary Switch

 

• Transitions (R, C, O)

 

(Add sleeve thickness for overall sleeved damper dimension)

 

Right hand drive is shown. Left hand drive is available upon request.

• PRV (pneumatic relief valve)

 

 

 

 

 

 

 

 

• Security Bars

 

• Sealed transitions and sleeves

Installation instructions available at www.greenheck.com

 

Page 1
Image 1
Greenheck Fan dimensions Model FSD-312, Combination Fire Smoke Dampers, Application, Ratings, Standard Construction