![Troubleshooting](/images/new-backgrounds/67459/6745913x1.webp)
Troubleshooting
WARNING: Before taking any corrective action, make certain unit is not capable of operation during repairs.
PROBLEM | CAUSE | CORRECTIVE ACTION | |
|
|
| |
| System resistance too high | Check system for proper operation of backdraft or | |
| control dampers; remove obstructions in ductwork, etc. | ||
|
| ||
|
|
| |
| Unit running backwards | See | |
|
|
| |
Reduced Airflow | Fan speed too low | Increase fan speed. | |
|
|
| |
| Excessive dirt buildup on | Clean wheel. | |
| wheel | ||
|
| ||
|
|
| |
| Improper wheel alignment | Center wheel on inlets. | |
|
|
| |
| Bad Bearings | Replace. | |
|
|
| |
| Belts too tight or too loose | Refer to Figure 4 and adjust tension. | |
|
|
| |
| Wheel improperly aligned and | Center wheel on inlets. See Figure 1. | |
| rubbing | ||
|
| ||
Excessive Noise |
|
| |
Loose drive or motor pulleys | Align and tighten. See | ||
or Vibration | |||
|
| ||
Foreign objects in wheel or | Remove objects, check for damage or unbalance. | ||
| |||
| housing | ||
|
| ||
|
|
| |
| Unbalance of wheel caused |
| |
| by excessive dirt and grease | Remove buildup. | |
| buildup |
| |
|
|
|
Maintenance Documentation
Job Information
Job Name:___________________________________ | Service Organization:__________________________________ |
Address:_____________________________________ | Address:_____________________________________________ |
City:_________________________________________ | City:_________________________________________________ |
State:________________ Zip:__________________ | State:________________ Zip:___________________________ |
Phone:_______________________________________ | Phone:_______________________________________________ |
Contact Person:______________________________ | Work Done By:________________________________________ |
Nameplate Information | Field | |
Model:_______________________________________ |
| |
Volts:_ ________ Hertz:_________ Phase:_______ | Actual Voltage:________ Hertz:_______ Phase:_________ | |
Amps:_______________ | Mark:_________________ | Actual Amperage:_____________________________________ |
Supply hp:___________ | Exhaust hp:___________ | Blower Rotation:______________________________________ |
Serial Number:________________________________ | Air Volume: Design cfm:______________________________ | |
Model Voltage:________________________________ | Actual cfm:______________________________ | |
Motor Amperage:_ ____________________________ | Level of fan (L or H):___________________________________ | |
Fan RPM:_ ___________________________________ | Fan RPM Range (min.)____________ (max.)______________ |
Series L: Models LB, LBP, LD, and LDP
®