Greenheck Fan SMD-401M dimensions Application Data, Damper Sideplate and Sleeve Dimensional Data

Models: SMD-401M

1 4
Download 4 pages 36.02 Kb
Page 3
Image 3

Application Data

Damper Sideplate and Sleeve Dimensional Data

The drawings below illustrate the factory standard sideplate and sleeve mountings for the SMD-401M. The standard "A" dimensions listed in the table provide adequate space for the mounting of actuators and controls.

If space constraints are a problem the "A" dimension can be varied between 5 38 in. (136mm) and 12 in. (305mm).

Sideplate

6 in.

 

 

"A" Dimension

 

 

 

 

 

 

in. (mm)

Sleeve

 

Sideplate

 

 

 

 

 

 

Standard

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

All Dampers*

7 3/16 (183)

 

12 (305)

 

6 3/16 (157)

 

 

 

 

 

 

When height is

11 3/16

 

12

 

10 3/16

11 in. (279) or

(284)

 

(305)

 

(259)

less with OCI

 

 

 

 

 

 

 

 

 

 

 

*With the exception of dampers 11 in. (279mm) high or less (12 in. (305mm)high or less if width is greater than 64 in. (1625mm)) with OCI option.

Sleeve

 

 

 

 

 

11/2" max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33/4"

Varies

53/8"

 

A

5 in.

12 in.**

**On dampers 11 in. (279mm) high or less (12 in. (305mm)high or less if width is greater than 64 in. (1625mm)) with OCI option, sideplate is 16 in.

(406mm)

A 5"

Sleeve Length

S

T*

Space Envelopes Required for

 

 

Actuators and Accessories

Externally mounted actuators always require space outside of the damper sideplate or sleeve. The “S” dimension illustrates the clearance required for various available actuators.

On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sideplate or sleeve. “B” and “T” dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated.

B*

Actuator Type/Model

B*

T*

S

 

 

With OCI

With OCI

 

 

 

 

 

 

 

Pneumatic

 

331-2976

2 1/2 in. (64mm)

5 1/4 in. (133mm)

6 in. (152m)

 

 

 

 

* For dampers 18 in.(457mm) or more in height these dimensions are 0 in.

1 Note: This actuator requires field calibration for the zero and span setting.

Page 3
Image 3
Greenheck Fan SMD-401M Application Data, Damper Sideplate and Sleeve Dimensional Data, Space Envelopes Required for