SECTION 2: CIRCUIT

REQUIREMENTS

220V Operation

Serious personal injury could occur if you connect the machine to the power source before you have com- pleted the set up process. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The 3 HP motor on the Model G0471 will draw the following amps:

G0471 Motor Draw

18 Amps

Circuit Requirements

Only connect your machine to a cir- cuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same cir- cuit. If you are unsure, consult a qualified electrician.

Minimum Circuit Requirement ..... 20 Amp

Plug/Receptacle Type

Plug Type ............. NEMA 6-20 (Figure 1)

Figure 1. Typical NEMA 6-20 plug and

receptacle.