440V Conversion

The Model G0502 can be converted for 440V 3-Phase operation. The procedure consists of changing the contactor and overload relay (see Figure 1), and rewiring the motor.

Order the Model G0502 440V Conversion Kit (P/N P0502144) by calling our Customer Service at (800) 523-4777.

Figure 1. Model G0502 440V conversion kit.

The 440V conversion procedure requires moderate electrical skill and knowledge, and the rewiring must be inspected by a licensed electrician before the saw is connected to power. Heed this warning to avoid the risk of serious personal injury from electrocution or damage to the saw.

To convert the Model G0502 for 440V opera- tion:

1.DISCONNECT SAW FROM POWER!

2.Open the electrical box, then replace the 220V contactor and overload relay with the ones in the conversion kit (see Figure 2).

Contactor

Overload

 

Trip

Relay

 

Load

 

 

Dial

 

 

 

Figure 2. Model G0502 contactor and overload

relay.

3.Make sure the trip load dial of the overload relay is set at 10 amps.

4.Wire the motor as shown on the inside of the motor wiring junction box cover for 440V operation.

Note: The illustration in Figure 3 is provided for your reference and was current at the time that this manual update was printed. However, always use the diagram on the wir- ing junction box cover that comes with your motor.

Figure 3. Model G0502 motor wiring for 440V

operation.

G0502 Manual Update