SECTION 2: CIRCUIT REQUIREMENTS

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The 134 HP motor on the Model G0573 will draw the following amps:

Motor Load

12-14 Amps

Circuit Breaker Requirements

Install your machine on a dedicated circuit to reduce the possibility of tripping the circuit break- er. If the circuit breaker frequently trips, have the circuit inspected by a qualified electrician. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.

Circuit Breaker

15 Amp

Plug Type

The Model G0573 is supplied with an inverted- type 5-15 plug. You must insert an extension cord receptacle over the inverted plug and then insert the male part of the extension cord into a 5-15 wall receptacle.

110V Operation Electrocution or fire could result if this machine is not grounded correctly or if your electrical configu- ration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician!

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

Make sure the cord is rated Standard Service (grade S) or better.

The extension cord must contain a ground wire and plug pin.

Use at least a 16 gauge cord.

DO NOT use a cord longer than 50 feet!.