SECTION 2: CIRCUIT REQUIREMENTS
Operation
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The motor for your machine may draw the follow- ing amps at maximum load.
G0596 at 110V | ............... 14 | Amps | |
G0597 at 220V | .............. 8.5 | Amps | |
G0598 at 220V | ............... 12 | Amps | |
G0599 at 220V | 10 | Amps |
Circuit Requirements
We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire
G0596 at 110V | 15 | Amp Circuit Breaker |
G0597 at 220V | 15 | Amp Circuit Breaker |
G0598 at 220V | 15 | Amp Circuit Breaker |
G0599 at 220V | Amp Circuit Breaker |
Plug Type
With the exception of the G0596, the cord set enclosed does not have a plug as the style of plug you require will depend upon the type of service you currently have or plan to install. We recom- mend using the following plugs for your machine on a dedicated circuit only (see Figures
G0597 at 220V | NEMA |
G0598 at 220V | NEMA |
G0599 at 220V | NEMA |
..220V Locking
Figure 1. NEMA 6-15 plug and receptacle.
��������
����������
�������
��������
������
�������������
Figure 2. NEMA 15-15R plug and receptacle.
|