Grizzly H6141 owner manual Troubleshooting, Symptom Possible Cause Possible Solution

Models: H6141

1 16
Download 16 pages 11.83 Kb
Page 12
Image 12

TROUBLESHOOTING

Symptom

Possible Cause

Possible Solution

 

 

 

 

 

Air leaking between

1.

Loose screws in housing.

1.

Tighten screws.

housing and hose.

2.

Damaged O-ring.

2.

Replace O-ring.

 

3.

Loose air fitting.

3.

Tighten air fitting and use

 

 

 

 

teflon tape.

 

 

 

 

 

Air leaking between

1.

Damaged gasket.

1.

Replace damaged gasket.

housing and cap

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

Tool skips on nail head

1.

Air leaks.

1.

Tighten screws and fittings.

while discharging.

2.

Dirt in cylinder.

2.

Clean cylinder and housing.

 

3.

Inadequate air flow to

3.

Check fitting, hose, compres-

 

 

tool.

 

sor and air pressure.

 

4.

Worn O-ring on piston or

4.

Replace piston O-ring.

 

 

lack of lubrication.

 

Lubricate.

 

5.

Gasket leaking.

5.

Replace gasket.

 

 

 

 

Tool drives nails too

1.

Broken spring.

1. Replace spring.

far; depth guide is

2.

Loose nose piece.

2.

Tighten nose piece and use

loose.

 

 

 

teflon tape.

 

 

 

 

 

Nailer does not fire.

1.

Piston shaft damaged.

1.

Replace piston shaft.

 

2.

Air pressure too low.

2.

Check/increase air pressure.

 

 

 

 

 

-12-

H6141 Air Palm Nailer

Page 12
Image 12
Grizzly H6141 owner manual Troubleshooting, Symptom Possible Cause Possible Solution