Grizzly H7669 instruction manual AssemblyControls

Models: H7669

1 20
Download 20 pages 39.5 Kb
Page 9
Image 9
AssemblyControls

AssemblyControls

1.Insert the filter into the gun body (see Figure 2).

Figure 2. Installing filter.

2.Screw the cup onto the top of the body.

3.Attach the air hose to the spray gun with a 14" NPS quick connect set-up (not included).

Note: You have the option of attach- ing the regulator/guage directly to the gun as shown in the photos. Some may find this awkward and would rath- er mount the regulator/gauge closer to the air source.

4.Attach the spray gun to an air hose regulated between 29 and 50 PSI.

Note: For the best results, use a hose that will be dedicated for spray use only. Do not use a hose that has been used with an in-line oiler or other pos- sible contaminant.

If you need additional help with this assem- bly, call our Technical Support at: (570) 546-9663.

Atomizing Cap

Cup

 

 

Fluid Control

Trigger

Pattern Control

 

Air Flow Control

 

Regulator/Gauge

 

Figure 3. Controls.

1.Fluid Control: Controls the volume of material that travels through the fluid tip.

2.Pattern Control: Adjusts the spray pattern from a round pattern to a wide fan.

3.Air Flow Control: Controls the fluid pressure inside the spray gun.

4.Atomizing Cap: Controls the spray pattern from vertical to horizontal.

5.Trigger: Two stage trigger. Stage one only releases compressed air for blowing off the work piece. Stage two sprays material.

6.Cup: 600 ml plastic cup allows easy viewing of material level. Includes a vented cap.

7.Regulator/Gauge: Regulates inlet air pressure to the spray gun. It can be attached directly to the gun for on- the-spot air adjustments or directly from the air source.

Note: DO NOT attach to an unregulat- ed air source that exceeds 120 PSI.

Model H7669 HVLP Spray Gun

-9-

Page 9
Image 9
Grizzly H7669 instruction manual AssemblyControls