Troubleshooting

Troubleshooting

.

Some solutions require disassembling gun. Always relieve system pressure and disconnect electrical cable before performing these procedures.

Problem

Cause(s)

Solution(s)

 

 

 

 

 

 

Material leaks from front of gun body

Seat or packing is worn

Replace seat (6) or packing (47).

 

Obstruction inside gun

Remove seat (6). Check and replace

 

 

if necessary.

 

Worn needle

Check and replace needle (4a) if nec-

 

 

essary.

 

 

 

Material leaks from back of gun body

Needle seal or packing is worn

Replace seals (4c) or packing (4d).

 

 

 

Gun does not shut off

Needle or seat is worn

Replace needle (4a) or seat (6).

 

Spring is broken or not installed cor-

Check and replace spring (14) if nec-

 

rectly

essary.

 

Obstruction inside gun

Remove seat (6). Check and replace

 

 

if necessary.

 

 

 

Gun does not heat material

Loose heater wires

Check and reconnect wire connec-

 

 

tions.

 

Loose sensor wires

Check and reconnect wire connec-

 

 

tions.

 

Heater cartridge failed

Replace failed heater.

 

Sensor failed

Replace failed sensor.

 

Temperature controller failed

Refer to Therm-O-Flow®200 manual

 

No power to heating circuitry

311208 as appropriate.

 

 

 

 

 

10

311209J

Page 10
Image 10
Haier 311209J important safety instructions Troubleshooting, Problem Causes Solutions