Attentions in Installation

Installation

(Figure 4)
During installation, adequate space must be reserved for future maintenance and
repair. If the water heater is installed within decoration boards, the right board
shall be removable to facilitate removing the plastic cover during maintenance.
City water inlet pressure shall not be less than 0.05 MPa,Maximum pressure can
not exceed 0.7MPa.
Electric water heater shall be installed indoors with ambient temperature above
0 . The pipes shall be collectively laid. Hot water outlet shall not be too far from
use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to
minimize heat loss.
The mounting wall shall be firm and reliable to support twice the weight of water
heater full of water. Non-load bearing walls or air brick walls must have
corresponding protective measures like additional support, wall-through screws or
back boards.
Electric water heater shall be located in a place easy for use, maintenance and
with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall
not be damaged. The installation location shall avoid being above toilet bowl,
bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling
to users.
Power socket for water heater shall be in a dry place free of water splash. (splash-
proof box is preferred).
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at
designated position with no random modification.
4

Safety Precautions

220V
50Hz
Haier
C
²»ÐУ¡
²»ÐÐ
Á¢
¼´ÓÃ
ÓÚÏ´Ô¡
²»
¿ÉÒÔ
²»
¿É
ÒÔ
Á¢
¼´
ÓÃÓÚ
Ï´
Ô¡
In case the power cord of the water heater is
damaged, be sure to have it replaced by after service
technicians with special cord offered by the
manufacturer.
Check if the ammeter and the diameter of the wires are in
accordance with the rated current of the water heater. If
necessary please have it checked by experienced
electrician.
The water heater adopts power supply of 220-240V ,
50/60Hz.
Be sure to use independent receptacle and earth it reliably.
The receptacle shall comply with the stipulation of
national standard.
The product adopts the patent "Safe Care" technology of our company. As long as adopting civil power supply,
even if the earthing wire is electrified by mistake, the "Safe Care" technology still can block the dangerous
electricity, and ensure your personal safety. But if you find perceptible current, please pull off the power plug
and contact local after service department for maintenance. Do not disassemble by yourself.

Description of the Symbols

Never do that

Be sure to act as per instructions

Set the receptacle of the water heater at dry
position away from water spraying. Do not insert
and pull the power plug with wet hands.
In winter of cold area, if the heater is idle for a long period,
please pull the handle of safety valve to discharge the
water. Otherwise it may freeze inside the water heater
and cause damages.
After installation, be sure to fill the heater completely with
water before switching on the power in the first usage.
Children must take bath under the supervision of adult.
In opening and closing the water valve, do not point
the shower head to human body. Otherwise it may
hurt by the spraying hot water.
The water may drip from the discharge pipe of the
pressure relied device and that this pipe must be
installed in a continuously downward direction and
in a frost-free environment. Check safety valve
once a month as follow: move the small handle of
safety valve, if there's water flowing out, safety
valve is normal; if there's no water flow, please
contact local after-sales service station.
The pressure relief device is to be operated
regularly to remove lime deposits and to verify that
it is not blocked. NO
pressure release hole