Outdoor unit

1.Installation of Outdoor Unit

2.Connection of pipes

Install according to

To bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius

should be 30 to 40 mm or longer.

Connecting the pipe of gas side first makes working easier.

The connection pipe is specialized for R410A.

Drawing for the installation of indoor and outdoor units

Half union Flare nut Forced fastening without careful
centering may damage the
threads and cause a leakage of
gas.
Pipe Diameter Fastening torque

Spanner Torque wrench

Liquid side 6.35mm(1/4") 18N.m
Gas side 9.52mm(3/8")
Gas side 12.7mm(1/2")
42N.m
55N.m
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over 7m, the function of the unit will be affected. If the pipe has
to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant
must be conducted by professional air conditioner engineer. Before adding additional refrigerant,
perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge
additional refrigerant.

3.Connection

Use the same method on indoor unit. Loosen
the screws on terminal block and insert the
plugs fully into terminal block, then tighten the
screws.
Insert the cable according to terminal number
in the same manner as the indoor unit.
If wiring is not correct, proper operation can
not be carried out and controller may be
damaged.
Fix the cable with a clamp.

4.Attaching Drain-Elbow

If the drain-elbow is used, please attach it as
figure.
Note: Only for heat pump unit. Drain hose
Drain elbow
CAUTION
In case the elevation A is more than 5m,
oil trap shoud be installed every 5~7m
Max. Length: Bmax1=15m
Max.Elevation:
Amax1=10m
In case the pipe length B is more than 7m,
the refrigerant should be charged, according to 20 g/m.
In case A is more than 5m
A
B
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
Oil trap
Amax2=15m Bmax2=25m
(07k 09k 12k)
(18k 22k)
(07k 09k 12k)
(18k 22k)