Emergency and Test Operation

Operation

Emergency and Test Operation

Emergency operation:

Use this operation only when the remote controller is defective or lost.

Emergency operation: When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.

Test operation: In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.

Temperature

Operation

Designated

Timer

Air flow

 

mode

temperature

mode

 

ABOVE 23OC

COOLING

26OC

NO

AUTOMATIC

BELOW 23OC

HEATING

23OC

NO

AUTOMATIC

Manual background It is not possible to operate in dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.

Manual background Continue to press the test operation switch for more Manual background than 5 seconds. After you hear the "Pi" sound twice, Manual background release your finger from the switch: the cooling operation Manual backgroundManual background starts with the air flow speed "Hi".

After 30 minutes, test operation ends automatically.

Removal of the restriction of emergency or test operation

Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.

When the remote controller is manipulated, it gets the system back to the normal operation mode.