Operation
When the remote controller is manipulated, it gets the system back to the
normal operation mode.

Removal of the restriction of emergency or test operation

Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.

Emergency operation

Test operation

Emergency and Test Operation (wall-mounted type)
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which means
the start of this operation.
In this operation, the system automatically selects
the operation modes, cooling or fan, according
to the room temperature.

It is not possible to operate in dry mode.

Temperature Operation
mode Designated
temperature Timer
mode Air flow
ABOVE 21OC
BELOW 21OC
COOLING
FAN 24OC
24OCNO
NO
AUTOMATIC
AUTOMATIC
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16OC, do not use it in the normal
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling operation
starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
emerg-
ency
emerg-
ency

19