Haier HSU-18LEA13(T3) Selection of Installation Place Outdoor Unit, Power Source, Indoor Unit

Models: HSU-18LEA13(T3)

1 8
Download 8 pages 44.68 Kb
Page 2
Image 2
Fixing of outdoor unit

256

140

500

140

Floor fixing dimensions of the outdoor unit (Unit:mm)

HSU-18LEA13(T3)

Fixing of outdoor unit

Indoor Unit Fix the unit to concrete or block with bolts( Selection of Installation Place Outdoor Unit10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Indoor Unit

Selection of Installation Place Outdoor Unit

Power Source Place, robust not causing vibration, where the body can be supported sufficiently.

Selection of pipe Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.

Manual background Place, possible to drain easily, where piping can be connected with the outdoor unit.

Manual background Place, where cold air can be spread in a room entirely.

Manual background Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Manual background Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.

Manual background In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are not increased.

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Place, where a distance marked Manual backgroundis available as illustrated in the above figure.

Power Source

Manual backgroundBefore inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Manual background Install an exclusive branch circuit of the power.

Manual background A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

Selection of pipe

Manual background To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation.

Manual background Use optional parts for piping set or pipes covered with equivalent insulation material.

 

 

 

For 18

 

 

 

 

Liquid pipe

(

)

6.35mm(1/4")

 

 

 

 

Gas pipe

(

)

12.7mm(1/2")

2

Page 2
Image 2
Haier HSU-18LEA13(T3) Selection of Installation Place Outdoor Unit, Power Source, Selection of pipe, Indoor Unit