Shutdown

Shutdown

1.Be sure all detergent is flushed from the system.

2.Turn off the pressure washer at on/off switch on unit.

3.Turn off the water supply.

4.After the motor and water supply are turned off, trigger the gun to depressurize system.

CAUTION: NEVER turn water supply off before turning motor off. Serious damage could occur to the pump and/or motor.

WARNING! NEVER disconnect the high-pressure discharge hose from machine while system is pressurized. To depressurize, turn motor off, turn water supply off and squeeze gun trigger 2-3 times.

5. After each use, wipe all surfaces of the pressure washer with a clean, damp cloth.

Storage

Do not store the pressure washer outdoors. Do not store the pressure washer where it might freeze. Damage due to freezing is not covered by the warranty.

Major Technical Data

ITEM

HP 1400

Working Pressure

7MPa(70 bar)

Working Flow Rate

5.7 l/min

Max. Pressure Water Supply

0.4MPa(4 bar)

Motor Capacity

1650W

Power Supply Voltage

240V~50Hz

Max. Water Temperature

50˚C

8

Customer Careline: 0845 601 7834