Hans Grohe 10011XX1, 10200XX1, 10201XX1, 10016XX1, 10015XX1 Assembly, Operation, Technical Data

Models: 10011XX1 10015XX1 10016XX1 10201XX1 10200XX1

1 8
Download 8 pages 31.49 Kb
Page 4
Image 4
Assembly

 

 

Assembly

 

 

 

1. Flush pipe lines thoroughly.

 

 

 

2. Place the mixer including the sealing washer in

 

 

position on the basin.

 

 

 

3. Slip the fixation piece including the washer over

 

 

the threaded pin and tighten the nut.

 

 

4. Connect the supply pipes to the supply valves:

 

 

hot-left; cold-right.

 

 

 

5. Connect the pop-up rod to the pop-up waste

 

 

assembly.

 

 

 

Large differences in pressure between the hot and

 

 

cold water supply should be balanced.

 

 

Operation

 

 

 

The mixer is actuated by pushing the lever head.

 

 

Swivel to the left = hot water,

 

 

 

swivel to the rigth = cold water.

 

 

 

Technical Data

 

 

 

Operating pressure:

max. 147 psi

 

 

Recommended operating press.:

14.7 - 72.5 psi

 

 

Test pressure:

232 psi

 

 

Hot water temperature:

max. 176° F

 

 

Recommended hot water temp.:

149° F

 

 

Hole size in deck:

 

hot

cold

Minimum:

1 1/4"

Maximum:

1 5/8"