Product Specification

Max. Flow Rate 2.2 gpm

 

Max. incoming water pressure

145 psi

Recommended water pressure

14.5 - 72 psi

Max. hot water temperature

176o F*

Recommended hot water temp

120oF - 140oF*

Hole size in mounting surface

 

18010001

1 1/4”

18210001

1 3/8”

Max. mounting surface thickness

1 5/8”

Model 18010001 has 10 mm supply hoses -- 10 mm - 3/8” adapters included.

No drain or pull rod is included with model 18010001. Grid drain 06400000 (not included) is recommended.

Model 18210001 has 3/8” supply hoses. 3/8” compression fittings are required (not included). A pop-up drain is included with 18210001.

*Know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachusetts, the water heater may be set no higher than 112oF.

Installation

Position the faucet and sealing ring on the mounting surface.

From beneath the mounting surface, install the fiber washer, metal washer, and mounting nut. Tighten the tensioning screws.

18010001 only: Install the adapters on the stops. Install the filters on the adapters.