![](/images/new-backgrounds/1060105/6010549x1.webp)
Justify the Handle
Turn the diverter handle to the handshower position.
Turn the temperature control knob until the output water is 100ºF.
Turn the diverter handle to the off position.
Loosen the handle screw with a 3 mm Allen wrench.
Remove the handle.
Align the indexing mark on the temperature control knob with the 100º mark.
1 |
2 |
3 |
Replace the handle. Tighten the handle screw. | 4 |
| |
| 25 |