Hans Grohe 27005XX1 installation instructions Troubleshooting, Problem Possible Cause Remedy

Models: 27005XX1

1 20
Download 20 pages 49.95 Kb
Page 15
Image 15

Troubleshooting

Problem

Possible Cause

Remedy

Insufficient water

- Supply pressure inadequate

- Check water pressure (If a pump

 

 

has been installed, check to see

 

 

if the pump is working).

 

- Filters on thermostat cartridge

- Clean thermostat filters

 

dirty

- Clean screen washer between

 

- Screen washer dirty

shower and hose

 

 

 

Crossflow, hot water being forced

- Check valves dirty or leaking

- Clean check valves, replace if

into cold water pipe, or vice

 

necessary

versa, when mixer is closed

 

 

 

 

 

Output temperature does not cor-

- Handle not justified

- Justify handle

respond with temperature set

- Hot water temperature too low

- Reset high temperature limit stop

 

 

 

Temperature regulation not pos-

- Temperature regulator dirty or

- Clean temperature regulator,

sible

calcified

replace if necessary

 

- Panel is cross-connected

- Connect supply hoses to correct

 

 

supplies

 

 

 

Safety stop override button not

- Spring defective

- Clean spring and/or button, re-

operating

- Button calcified

place if necessary

 

 

 

Diverter control stiff

- Diverter cartridge defective or

- Replace cartridge

 

dirty

 

15

Page 15
Image 15
Hans Grohe 27005XX1 installation instructions Troubleshooting, Problem Possible Cause Remedy