Installation Instructions
Turn off the water at the supply before beginning the installation.
·Remove the caps from the plaster shields. Cut the plaster shields 1 mm (1/16”) from the surface of the finished wall. Seal around the plaster shields with a suitable,
·Use a 27 mm deep socket wrench to remove the flush insert.
·Use a 17 mm deep socket wrench to remove the plug from the spout port.
·Install the cartridge and anti twist device to the cartridge housing. Make sure that the cartridge is oriented as shown in the diagram.