7.Fit Suction Hose [1] over the Vacuum Body with Air Switch Assembly [10].
8.To connect the Hose to an Abrasive Blast Cabinet (not included), unscrew the Connecting Nut
Air Connection
DUST
COLLECTOR
Note: Air Compressor is not supplied.
1.You will need to prepare a 1/2” Air Connector (not included with this product) and connect it to the valve located on the Vacuum Body with Air Switch Assembly.
2.Wrap the Air Connector with a pipe thread seal tape before connecting to a 3/8” I.D. Air Source Hose (not included). Connect the Air Source Hose to the Valve.
3.Air pressure should not exceed 125 psi.
This air powered product requires lubrication during operation. For best results, it is recommended to have an oiler and water filter in line with the air supply as shown. This will extend the life of the product.
Operation
The product is intended for use with a
1.Follow instructions in Step 8, above, for connecting the Hose to the Sand Blast Cabinet.
2.Connect the Dust Collector to the Air Compressor according to the instructions on Page 5, “Air Connection.”
3.Use the Air Switch attached to the Air Switch Assembly to control the amount of air flow through the product. Air Compressor pressure should not exceed 125 psi.
SKU 2448 | Page 5 |