Troubleshooting
Problem |
| Possible Causes |
| Likely Solutions |
|
Compressor does | 1. | Incorrect power supply. | 1. | Check that circuit matches compressor requirements. | |
not start or restart | 2. | No power at outlet. | 2. | Reset circuit breaker, or have outlet serviced by a | |
|
|
|
| qualified technician. |
|
| 3. | Power cord not plugged in | 3. | Check that cord is plugged in securely. |
|
|
| properly. |
|
|
|
| 4. | Thermal overload switch | 4. | Turn off tool. Turn off Compressor and wait for it to cool | |
|
| tripped or Compressor circuit |
| down. Press Reset Button. Resume operation. | |
|
| breaker tripped. |
|
|
|
| 5. | Building power supply circuit | 5. | Reset circuit or replace fuse. Check for low voltage | |
|
| tripped or blown fuse. |
| conditions. It may be necessary to disconnect other | |
|
|
|
| electrical appliances from the circuit or move the | |
|
|
|
| compressor to its own circuit. |
|
| 6. | Tank already pressurized. | 6. | Fully bleed tank of air. |
|
| 7. | Cord wire size is too small or | 7. | Use larger diameter or shorter extension cord or | |
|
| cord is too long to properly |
| eliminate extension cord. See Recommended Wire | |
|
| power compressor. |
| Gauge for Extension Cords in Safety section. | |
| 8. | Compressor needs service. | 8. | Have unit inspected by a qualified technician. | |
Compressor shuts | 1. | Cold weather | 1. | Turn off tool. Press the Reset Button. Start | |
off automatically |
|
|
| Compressor in a heated area if temperatures drop | |
before reaching full |
|
|
| below 32ºF, or use SAE 10W | |
pressure (Circuit |
|
|
| compressor oil instead of 30W. |
|
breaker trips) | 2. | Extension cord usage. | 2. | Turn off tool. Press the Reset Button. Use without | |
|
|
|
| extension cord. |
|
Compressor | 1. | Cold weather. | 1. | Press the Reset Button, then, start Compressor in a | |
hums, then shuts |
|
|
| heated area if temperatures drop below 32ºF, or use | |
off automatically |
|
|
| SAE 10W | |
before reaching full |
|
|
| 30W. |
|
pressure (Circuit | 2. | Extension cord usage. | 2. | Press the Reset Button. Use without extension cord. | |
breaker trips) |
|
|
|
|
|
| 3. | Engine too hot. | 3. | Wait for engine to cool and unit will start automatically. | |
Compressor builds | 1. | Incorrect power supply. | 1. | Check that circuit matches compressor requirements. | |
pressure too slowly | 2. | Crankcase overfilled with oil or | 2. | Drain oil and refill to proper level with recommended | |
|
| oil too thick. |
| oil. |
|
| 3. | Working environment too cold. | 3. | Move unit to a warmer location. Check that | |
|
|
|
| recommended oil is in crankcase. |
|
| 4. | Safety valve needs service. | 4. | Listen for air leaking from valve. If leaking replace with | |
| 5. | Loose fittings. |
| identical valve with same rating. |
|
| 5. | Reduce air pressure, then check all fittings with a soap | |||
|
|
|
| solution for air leaks and tighten as needed. Do not | |
|
|
|
| overtighten. |
|
Compressor not | 1. | Filters need cleaning/replacing. | 1. | Check inlet and outlet filters. Clean and/or replace as | |
building enough air |
|
|
| needed. |
|
pressure | 2. | Crankcase oil too thick. | 2. | Drain oil and refill to proper level with recommended | |
|
|
|
| oil. |
|
| 3. | Check Valve needs service. | 3. | Clean or replace, as needed. |
|
| 4. | Compressor not large enough | 4. | Check if accessory SCFM is met by Compressor. If | |
|
| for job. |
| Compressor cannot supply enough air flow (SCFM), | |
|
|
|
| you need a larger Compressor. |
|
| 5. | Loose fittings. | 5. | Reduce air pressure, then check all fittings with a soap | |
|
|
|
| solution for air leaks and tighten as needed. Do not | |
|
|
|
| overtighten. |
|
| 6. | Hose or hose connections not | 6. | Replace with larger hose and/or hose connections. | |
|
| adequate. |
|
|
|
| 7. | High altitude reducing air | 7. | You may need a larger compressor if you are situated | |
|
| output. |
| in a high altitude location. |
|
Page 16 | For technical questions, please call | SKU 67847 |