Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

 

Compressor does

1.

Incorrect power supply.

1.

Check that circuit matches compressor requirements.

not start or restart

2.

No power at outlet.

2.

Reset circuit breaker, or have outlet serviced by a

 

 

 

 

qualified technician.

 

 

3.

Power cord not plugged in

3.

Check that cord is plugged in securely.

 

 

 

properly.

 

 

 

 

4.

Thermal overload switch

4.

Turn off tool. Turn off Compressor and wait for it to cool

 

 

tripped or Compressor circuit

 

down. Press Reset Button. Resume operation.

 

 

breaker tripped.

 

 

 

 

5.

Building power supply circuit

5.

Reset circuit or replace fuse. Check for low voltage

 

 

tripped or blown fuse.

 

conditions. It may be necessary to disconnect other

 

 

 

 

electrical appliances from the circuit or move the

 

 

 

 

compressor to its own circuit.

 

 

6.

Tank already pressurized.

6.

Fully bleed tank of air.

 

 

7.

Cord wire size is too small or

7.

Use larger diameter or shorter extension cord or

 

 

cord is too long to properly

 

eliminate extension cord. See Recommended Wire

 

 

power compressor.

 

Gauge for Extension Cords in Safety section.

 

8.

Compressor needs service.

8.

Have unit inspected by a qualified technician.

Compressor shuts

1.

Cold weather

1.

Turn off tool. Press the Reset Button. Start

off automatically

 

 

 

Compressor in a heated area if temperatures drop

before reaching full

 

 

 

below 32ºF, or use SAE 10W non-detergent air

pressure (Circuit

 

 

 

compressor oil instead of 30W.

 

breaker trips)

2.

Extension cord usage.

2.

Turn off tool. Press the Reset Button. Use without

 

 

 

 

extension cord.

 

Compressor

1.

Cold weather.

1.

Press the Reset Button, then, start Compressor in a

hums, then shuts

 

 

 

heated area if temperatures drop below 32ºF, or use

off automatically

 

 

 

SAE 10W non-detergent air compressor oil instead of

before reaching full

 

 

 

30W.

 

pressure (Circuit

2.

Extension cord usage.

2.

Press the Reset Button. Use without extension cord.

breaker trips)

 

 

 

 

 

 

3.

Engine too hot.

3.

Wait for engine to cool and unit will start automatically.

Compressor builds

1.

Incorrect power supply.

1.

Check that circuit matches compressor requirements.

pressure too slowly

2.

Crankcase overfilled with oil or

2.

Drain oil and refill to proper level with recommended

 

 

oil too thick.

 

oil.

 

 

3.

Working environment too cold.

3.

Move unit to a warmer location. Check that

 

 

 

 

recommended oil is in crankcase.

 

 

4.

Safety valve needs service.

4.

Listen for air leaking from valve. If leaking replace with

 

5.

Loose fittings.

 

identical valve with same rating.

 

 

5.

Reduce air pressure, then check all fittings with a soap

 

 

 

 

solution for air leaks and tighten as needed. Do not

 

 

 

 

overtighten.

 

Compressor not

1.

Filters need cleaning/replacing.

1.

Check inlet and outlet filters. Clean and/or replace as

building enough air

 

 

 

needed.

 

pressure

2.

Crankcase oil too thick.

2.

Drain oil and refill to proper level with recommended

 

 

 

 

oil.

 

 

3.

Check Valve needs service.

3.

Clean or replace, as needed.

 

 

4.

Compressor not large enough

4.

Check if accessory SCFM is met by Compressor. If

 

 

for job.

 

Compressor cannot supply enough air flow (SCFM),

 

 

 

 

you need a larger Compressor.

 

 

5.

Loose fittings.

5.

Reduce air pressure, then check all fittings with a soap

 

 

 

 

solution for air leaks and tighten as needed. Do not

 

 

 

 

overtighten.

 

 

6.

Hose or hose connections not

6.

Replace with larger hose and/or hose connections.

 

 

adequate.

 

 

 

 

7.

High altitude reducing air

7.

You may need a larger compressor if you are situated

 

 

output.

 

in a high altitude location.

 