Replacing Backing Pad (31)
1.Disconnect air pressure hose from tool
2.Place Wrench (36) onto Pad Retainer (38) and hold firmly.
3.Place Backing Pad (31) on Pad Retainer (38) and turn clockwise to attach. Hand tighten firmly.
Maintenance
1.Place a few drops of light weight air tool oil (not included) into the Regulator each time before using the tool.
2.After each use, drain any accumulated moisture from the tool, and spray a small amount of water displacing oil into and on the tool. Wipe clean.
3.Store tool in a safe location out of reach of children and unauthorized persons.
Troubleshooting
Tool will not operate.
1.Possible cause: Low or no air pressure.
Solution: Check air compressor to be sure it is operating properly. Check Air Regulator. Check air lines for leaking or blockage.
2.Possible cause: Corroded Rotor (39).
Solution: Spray light weight penetrating oil into the Regulator. If tool still won’t operate, take it to a qualified service technician for repair.
3.Possible Cause: Damaged Seals or O rings.
Solution: Take it to a qualified service technician for repair.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.