Harbor Freight Tools 95014 Figure E, Figure D, For technical questions, please call

Models: 95014

1 16
Download 16 pages 16.72 Kb
Page 10
Image 10
FIGURE D

7.IMPORTANT TIP: If the humidity is 90 to 100%, the Water Trap (17) will not be able to trap all of the moisture in a 3/4 full Tank (1). It is recommended to reduce the amount of media, load more frequently, and empty the Water Trap more often. This will reduce the possibility of clogging the bottom of the Tank or the line. (See Figure D.)

FUNNEL

(29)

WATER TRAP

(17)PRESSURE GAUGE

(15)

TANK

FILLER CAP

(12)

AIR SUPPLY VALVE

(18)

TANK

(1)

FIGURE D

8.Depending on the size (diameter) of the media, install the proper size Ceramic Nozzle (37C) onto the Blast Gun. To do so, unscrew and remove the Nozzle Cap Nut (39C). Position the Nozzle Gasket (36C) against the Adapter (35C). Position the proper Ceramic Nozzle (2.0mm, 2.5mm, or 3.0mm) against the Nozzle Gasket. Then screw the Nozzle Cap Nut back onto the Adapter to secure the Nozzle Gasket and Ceramic Nozzle in place. (See Figure E.)

CONTROL LEVER (42C)

NOZZLE CAP NUT

(39C) CERAMIC NOZZLE

(37C)

FIGURE E

NOZZLE GASKET

ADAPTER

(36C)

(35C)

SKU 95014

For technical questions, please call 1-800-444-3353

PAGE 10

Page 10
Image 10
Harbor Freight Tools 95014 operating instructions Figure E, Figure D, For technical questions, please call