Harman SF160 manual Maintenance, Specifications SF-160 SF-260 SF-360

Models: SF160

1 24
Download 24 pages 46.6 Kb
Page 13
Image 13

Maintenance

The spiral chamber is basically self-cleaning. However, if there is a draft problem and you have been burning wood for a long time with little demand, the spiral chamber will need to be cleaned. To clean the spiral chamber, remove the stovepipe and scrape any creosote or debris from the top and front of the chamber. The rear of the chamber should not have much accumulation. If it does, clean it out.

NOTE: 1/4” to 1/2” of creosote in the spiral chamber is normal.

The pipes inside the firebox will accumulate creosote if the demand for heat is too low, when burning wood. 1/8” to 1/4” of creosote is normal on the pipes and firebox walls. If more creosote has accumulated, it should be scraped off of these surfaces.

NOTE: Creosote in the firebox can be burned off by burning coal for a few days.

The fire bricks may become cracked during the course of normal operation. A cracked brick that is still in place, is still doing its job, and need not be replaced immediately. If a brick is broken, and has fallen out of place, it should be replaced before any further burning occurs. The firebricks used in the Trident Boiler are available for replacement from your Harman dealer.

Gaskets on the doors are there to regulate air to the firebox. If a gasket is failing, you’ll notice difficulty in controlling the fire. Inspect the gaskets regularly, and replace with Harman supplied material only.

Specifications

SF-160

SF-260

SF-360

Heating Capacity (Square Feet)

2200 Max.

3200 Max.

4500 Max.

Approximate BTU per hour (wood or coal)

90,000

130,000

180,000

AMP Rating

40

40

40

Water Capacity (US Gallon)

25

32

42

Weight

640 Lbs

780 Lbs

925 Lbs

 

 

 

 

Hydro-Pressure Tested

Yes

Yes

Yes

Firebox Dimensions (inches)

16W x 22L x 19H

18W x 26L x 20H

18W x 30L x 25H

 

 

 

 

Recommended Log Length (inches)

19

23

27

Door Opening Size (inches)

11 x 13

13 x 13

13 x 13

 

 

 

 

Overall Dimensions (inches)

23W x 23.5L x 45H

26W x 27.5L x 45.5H

26W x 31.5L x 51.5H

Flue Size (diameter)

6 inch

7 inch

7 inch

Flue Height (top of flue)

37.5 inches

38.75 inches

44 inches

 

 

 

 

Number Of Grates (10 Lbs. Each)

4

5

6

Type Of Fuel

Coal / Wood

Coal / Wood

Coal / Wood

 

 

 

 

Water Inlet and Outlet Size

1.25 NPT

1.25 NPT

1.25 NPT

Automatic Draft Control

Yes

Yes

Yes

 

 

 

 

Aquastat

Yes

Yes

Yes

Temperature / Pressure Gauge

Yes

Yes

Yes

ASME Pressure Relief Valve

Yes

Yes

Yes

Ash Pan With Handle

Yes

Yes

Yes

Domestic Hot Water Coil (optional)

4 GPM

4 GPM

4 GPM

 

 

 

 

Approximate BTU per hour (electric option)

30,000

30,000

30,000

Kilowatt Rating (electric option)

9

9

9

 

 

 

 

13